Description: Interlocks RAP 311-300-00-120 The docking interlock is open during run mode. 311-302-00-120 The top cover interlock is open during run mode. 311-303-00-120 The front door interlock is open during run mode.
Remedy: Go to Flag 1. Check for +24V on pin 1. If the voltage is not present, refer to 311C-120 1K LCSS Power Distribution RAP. Go to the appropriate procedure: • 311-300-00-120 Docking Interlock Checkout • 311-302-00-120 Top Cover Interlock Checkout • 311-303-00-120 Front Door Interlock Checkout 311-300-00-120 Docking Interlock Checkout Undock the 1K LCSS, refer to-120., check the docking interlock switch, S11-300 as follows: • While supporting the 1K LCSS, slide the 1K LCSS 5cm (2 inches) away from the machine. Check the interlock actuator on the machine is not damaged or missing. NOTE: The wiring harness passes underneath the docking interlock switch housing. If this harness is not correctly positioned, the switch can be mis-located, giving intermittent docking interlock problems. • Enter dC330 code 011-300, docking interlock switch, S11-300. While supporting the 1K LCSS, slide the 1K LCSS 5cm (2 inches) away from the machine to de-actuate S11-300. If the display does not change, refer to: – GP 13, How to Check a Switch – P/J6, 1K LCSS PWB • Go to Flag 1. Check the wiring between P/J5 and S11-300. • If necessary, install a new docking interlock switch, PL 11.102 Item 2. 311-302-00-120 Top Cover Interlock Checkout Check the top cover interlock switch, S11-302 as follows: • Check the switch actuator. • Enter dC330 code 011-302, top cover interlock switch, S11-302. Actuate S11-302. If the display does not change, refer to: – GP 13, How to Check a switch –. – P/J5, 1K LCSS PWB • Go to Flag 3. Check the wiring between P/J6 and S11-302. • If necessary, install a new top cover interlock switch, PL 11.124 Item 6. 311-303-00-120 Front Door Interlock Checkout Check the front door interlock switch, S11-303 as follows: • Check the switch actuator. • Enter dC330 code 011-303, front door interlock switch, S11-303. Actuate S11-303. If the display does not change, refer to: – GP 13, How to Check a switch –. – P/J5, 1K LCSS PWB • Go to Flag 2. Check the wiring between P/J5 and S11-303. • If necessary, install a new front door interlock switch, PL 11.124 Item 5. Perform SCP 5 Final Actions.