Description: Paddle Unit Position RAP 311-465-00-171 The paddle unit has failed to return to the upper position. 311-466-00-171 The paddle unit has failed to move from the upper position. 311-467-00-171 The paddle unit has failed to return to the lower position. 311-468-00-171 The paddle unit has failed to move from the lower position.
Remedy: NOTE: All HVF BM interlocks must be made to supply +24V to the motors. Enter dC330 code 011-027 paddle unit motor, MOT11-027. Press Start. MOT11-027 runs. Y↓N→Go to Flag 2. Check MOT11-027. Refer to: • GP 10, How to Check a Motor. • P/J202, HVF Control PWB. • 311A-171 HVF Power Distribution RAP. Install new components as necessary: • Paddle module driving motor assembly, PL 11.150 Item 6. • HVF control PWB, PL 11.157 Item 2. Enter dC330 code 011-027 to check the paddle unit motor, MOT11-027. The paddle unit moves. Y↓N→Check the drive gears on the paddle unit. Install new components as necessary. PL 11.145 Item 2. Enter dC330 code 011-194 paddle unit upper sensor, Q11-194. Press Start. Select code 011- 027 and press start. The sensor status changes. Y↓N→Go to Flag 1. Check Q11-194. Refer to: • GP 11 How to Check a Sensor. • P/J201, HVF Control PWB • 311A-171 HVF Power Distribution RAP. Install new components as necessary: • Paddle module assembly, PL 11.145 Item 2. • HVF control PWB, PL 11.157 Item 2. Enter dC330 code 011-195 paddle unit lower sensor, Q11-195. Select code 011-195 and press Start. Select code 011-027 and press start. The sensor status changes. Y↓N→Go to Flag 3. Check Q11-195. Refer to: • GP 11 How to Check a Sensor. • P/J201, HVF Control PWB. • 311A-171 HVF Power Distribution RAP. Install new components as necessary: • Paddle module assembly, PL 11.145 Item 2. • HVF control PWB, PL 11.157 Item 2. Perform SCP 5 Final Actions.