Description: SPDH Scanner Calibration Faults RAP 366-450-00 Dark range status bit is not clear prior to calibration. 366-451-00 Dark range status bit is not set after calibration. 366-452-00 Pixel offset status bit is not clear prior to calibration. 366-453-00 Pixel offset status bit is not set after calibration. 366-454-00 Gain range status bit is not clear prior to calibration. 366-455-00 Gain range status bit is not set after calibration. 366-456-00 Pixel gain status bit is not clear prior to calibration. 366-457-00 Pixel gain status bit is not set after calibration. 366-458-00 Highest Intensity image pixel value exceeds maximum tolerance. 366-459-00 Pixel error exceeds maximum adjustment allowed during dark calibration. 366-460-00 Pixel error exceeds maximum adjustment allowed during dark calibration. 366-461-00 Highest Intensity image pixel value is lower than the minimum tolerance. 366-462-00 Pixel error exceeds maximum adjustment allowed during white calibration. 366-463-00 Pixel error exceeds maximum adjustment allowed during white calibration. 366-466-00 Pixels out range during black calibration. 366-467-00 Pixels out range during white calibration. 366-468-00 Pixel clock error from the full width array.
Remedy: Perform ADJ 60.5 IIT Registration, Magnification and Calibration. The fault is still present. Y↓N→Go to SCP 5 Final Actions. Go to Flag 1, disconnect then check the Side 2 scan assembly data ribbon cable and connectors P/J451 on the side 2 CCD PWB and P/J413 on the scanner PWB. The ribbon cable and connectors are clean and undamaged. Y↓N→Clean or repair the ribbon cable or connectors., if necessary install new components: • Side 2 scan assembly data ribbon cable, PL 5.10 Item 16. • Side 2 scan assembly, PL 5.10 Item 12. • Scanner PWB, PL 60.20 Item 4. Reconnect the P/J451 to P/J413 Side 2 scan assembly data ribbon cable. Go to Flag 2. Disconnect then check the SBC PWB/Scanner PWB data cable and connectors P/J411 on the scanner PWB and P/J250 on the SBC PWB. The data cable and connectors are clean and undamaged. Y↓N→Clean or repair the cable connectors. Install new components as necessary: • SBC PWB/Scanner PWB data cable, PL 3.22 Item 20. • Scanner PWB, PL 60.20 Item 4. If the fault remains, perform the 303D SBC PWB Diagnostics RAP. Perform dC301 scanner system NVM initialization, then ADJ 60.5 IIT Registration, Magnification and Calibration. If the fault persists reload the software using the AltBoot Software Loading Procedure, go to GP 4 Machine Software.