Mã lỗi 393-310-00, 393-390-00 — Xerox WorkCentre 5865

Code: 393-310-00, 393-390-00

Description: Low Toner Sensor Failure RAP 393-310-00 The toner cartridge motor continues to dispense toner for a period greater than 12 seconds after the low toner sensor detects that the toner dispense module is full. 393-390-00 The low toner sensor detects that the toner level is low for a period greater than 70 seconds after toner cartridge motor start.
Remedy: NOTE: The door interlock switch must be cheated when checking +24V components. NOTE: The toner cartridge motor will time out after 5 seconds. Cheat the door interlock switch. Enter dC330 code 093-045 toner cartridge motor, MOT93-045. Press start. Observe the toner cartridge. The toner cartridge rotates. Y↓N→The motor runs. Y↓N→Go to Flag 1. Check MOT93-045. Refer to: • GP 10 How to Check a Motor. •. • P/J6, IOT PWB. • 301G +24V Distribution RAP • 301B 0V Distribution RAP. Install new components as necessary: • Toner dispense module, (45-55 ppm) PL 90.17 Item 1 or (65-90 ppm) PL 90.15 Item 1. • Developer module, (45-55 ppm) PL 90.17 Item 2 or (65-90 ppm) PL 90.15 Item 2. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. Check the toner dispense drive gears and. If necessary install a new toner dispense module, (45-55 ppm) PL 90.17 Item 1 or (65-90 ppm) PL 90.15 Item 1. Perform the following: 1. Remove the developer module. 2. Remove the toner cartridge motor MOT93-045 (2 screws). 3. Remove the lid of the toner hopper using a small flat bladed screwdriver. 4. Remove the toner from the hopper and clean all toner from the face of the low toner sensor Q93-310 using a toner vacuum and a brush. 5. Re-assemble and install the developer assembly. 6. Keep the front door open to prevent the toner cartridge motor from being energised. 7. Switch on the machine, GP 14. The voltage at PJ93 pin 7 is 0V. Y↓N→Go to Flag 2. Check Q93-310. Refer to: • GP 11 How to check a sensor •, P/J6, IOT PWB • 301B 0V Distribution RAP • 301E +5V Distribution RAP Install new components as necessary: • Low toner sensor, (45-55 ppm) PL 90.17 Item 5 or (65-90 ppm) PL 90.15 Item 5 • Developer module, (45-55 ppm) PL 90.17 Item 2 or (65-90 ppm) PL 90.15 Item 2 If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. The voltage at P/J6 pin 7 is 0V. Y↓N→Go to Flag 2, Check the wiring and connectors, Refer to. Cheat the front door interlock switch. The toner cartridge will now rotate as toner is dispensed into the toner hopper. The voltage at PJ93 pin 7 is changes to +3.3V and the toner cartridge stops rotating. Y↓N→Go to Flag 2. Check Q93-310. Refer to: • GP 11 How to check a sensor •, P/J6, IOT PWB • 301B 0V Distribution RAP • 301E +5V Distribution RAP Install new components as necessary: • Low toner sensor, (45-55 ppm) PL 90.17 Item 5 or (65-90 ppm) PL 90.15 Item 5 • Developer module, (45-55 ppm) PL 90.17 Item 2 or (65-90 ppm) PL 90.15 Item 2 If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. The fault may be intermittent, due to toner bridging inside the toner cartridge. Install a new toner cartridge, (45-55 ppm) PL 90.17 Item 4 or (65-90 ppm) PL 90.15 Item 4. Check the image quality then perform SCP 5 Final Actions.

← Xem tất cả mã lỗi Xerox WorkCentre 5865

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie