Description: Lead Edge Late to Fuser Exit Switch RAP (65-90 ppm) 310-101-00 The lead edge of the paper failed to actuate the fuser exit switch within the correct time after the registration clutch was energized for a simplex sheet. 310-102-00 The lead edge of the paper failed to actuate the fuser exit switch within the correct time after the registration clutch was energized for a duplex sheet side 1. 310-103-00 The lead edge of the paper failed to actuate the fuser exit switch within the correct time after the registration clutch was energized for a duplex sheet side 2.
Remedy: NOTE: The door interlock switch must be cheated when checking +24V components. Enter dC330 code 010-100 fuser exit switch, S10-100. Press Start. Manually actuate the switch with a piece of paper. The display changes. Y↓N→Go to Flag 1. Check S10-100. Refer to: • GP 13 How to Check a Switch. •. • P/J35, IOT PWB. • 301D +3.3V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new fuser exit switch, PL 10.10 Item 11. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. W/TAG 001 machines only. Enter dC330 code 010-065 vacuum transport fan, MOT10-065.. Press Start, The fan runs. Y↓N→Go to Flag 2. Check MOT10-065. Refer to: • GP 10 How to Check a Motor. •. • P/J5, IOT PWB. • P/J17, LVPS. • Fuse, PL 1.10 Item 9, GP 7. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new short paper path assembly, PL 10.25 Item 1. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. Enter dC330 code 042-010 main drive motor. Press Start. Add code 82-070 registration clutch, CL82-070. Press Start. NOTE: The clutch will switch off after 5 seconds. The jam clearance knob 4c, PL 80.17 Item 10, rotates. Y↓N→Go to Flag 3. Check CL82-070. Refer to: • GP 12 How to Check a Solenoid or Clutch. • P/J5, IOT PWB. • P/J17, LVPS. • Fuse, PL 1.10 Item 9, GP 7. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new registration clutch, PL 80.17 Item 7. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. Enter dC330 code 082-150 registration sensor, Q82-150. Press Start. Manually actuate the sensor with a piece of paper. The display changes. Y↓N→Go to Flag 4. Check Q82-150. Refer to: • GP 11 How to Check a Sensor. •. • P/J16, IOT PWB. • 301E +5V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new registration sensor, PL 80.17 Item 3. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. Check the following components, refer to GP 7: • Registration roll, PL 80.17 Item 9. • W/TAG 001 machines only. Roll assembly on the short paper path assembly, PL 10.25 Item 16. • Check the detack corotron and the connection to the HVPS. Refer to 391-060-00 HVPS Fault RAP • The drive gear on the fuser module, PL 10.10 Item 1. • The fuser drive gear on the main drives module, PL 40.12 Item 10. • Fuser web motor and the fuser web, refer to the 310A Fuser Web Motor RAP. • Check the drives plate on the registration clutch for damage and contamination. Refer to the replacement procedure. • If the fault remains, the +24V supply from the LVPS may be faulty. Perform the 301L LVPS Checkout RAP.