Description: Interlocks RAP 311-300-00-150 The docking interlock is open during run mode. 311-302-00-150 The top cover interlock is open during run mode. 311-303-00-150 The front door interlock is open during run mode.
Remedy: Go to Flag 1. Check for +24V on P/J302 pin 1. If the voltage is not present, refer to 311D-110 LVF BM Power Distribution RAP. Go to the appropriate RAP: • 311-300-00-150 Docking Interlock RAP • 311-302-00-150 Top Cover Interlock RAP • 311-303-00-150 Front Door Interlock RAP 311-300-00-150 Docking Interlock RAP Un-dock the LVF BM-150, Check the docking interlock switch, S11-300 as follows: • Check the interlock actuator on the machine is not damaged or missing. • Enter dC330, code 011-300. Actuate the switch, if the display does not change, refer to: – GP 13, How to Check a Switch –. – P/J302, LVF PWB. • Go to Flag 1. Check the wiring between P/J302 and the switch. • If necessary, install a new switch, PL 11.52 Item 2. 311-302-00-150 Top Cover Interlock RAP Check the top cover interlock switch, S11-302 as follows: • Check the switch actuator. • Enter dC330, code 011-302. Actuate the switch, if the display does not change, refer to: – GP 13, How to Check a switch –. – P/J315, LVF PWB. • Go to Flag 3. Check the wiring between P/J315 and the switch. • If necessary, install a new switch, PL 11.76 Item 6. 311-303-00-150 Front Door Interlock RAP Check the front door interlock switch, S11-303 as follows: • Check the switch actuator. • Enter dC330, code 011-303. actuate the switch, if the display does not change, refer to: – GP 13, How to Check a switch –. – P/J302, LVF PWB. • Go to Flag 2. Check the wiring between P/J302 and the switch. • If necessary, install a new switch, PL 11.76 Item 5. Perform SCP 5 Final Actions.