Description: ROS Motor Failure RAP 361-020-00 This fault code has two failure modes: • The ROS motor ready signal was not received by the IOT PWB within the set time of the ROS being powered on. • The IOT PWB recognizes a change of state of the ROS motor ready signal during operation.
Remedy: Switch off the machine, then switch on the machine, GP 14. The 361-020 fault still exists. Y↓N→Perform SCP 5 Final Actions. Enter the dC330 output code 061-020 and listen for the ROS motor. The ROS motor gives a distinctive ascending frequency sound, of a short duration (5 to 6 seconds) during transition from standby to run. Y↓N→The xerographic module is fully home and the front door is fully closed or the front door interlock is cheated. Y↓N→Correct the condition. If necessary go to the 301-300-00 Front Door Open RAP. Go to Flag 1. Check the following voltages at P/J18 on the LVPS: • +24V between pins 1 and 2. • +3.3V between pins 3 and 4. The voltages are good. Y↓N→Go to the relevant RAP: • 301B 0V Distribution RAP, refer to the 3.3V return and 24V return. • 301D +3.3V Distribution RAP. • 301G +24V Distribution RAP. Enter the dC330 output code 061-020 to run the ROS motor. Go to Flag 2. 0V is available at P/J2 pin 1 on the IOT PWB. Y↓N→Go to Flag 3. 0V is available at P/J2 pin 6 on the IOT PWB. Y↓N→Perform the OF7 IOT PWB Diagnostics RAP. NOTE: To disconnect P/J1 and P/J2 the ROS must be removed from the machine, refer to. The ROS PWB may not be marked with the correct PJ numbers, where P/J1 and P/J2 are connected. P/J1 can be identified as a four way power harness. P/J2 can be identified as a seven way signal harness. Go to Flag 1, Flag 2 and Flag 3. Disconnect P/J1 and P/J2. Check the wiring. The wiring is good. Y↓N→Repair the wiring. Install a new ROS, PL 60.10 Item 4. Perform the OF7 IOT PWB Diagnostics RAP. Go to Flag 2. 0V is available at P/J2 pin 1. Y↓N→NOTE: To disconnect P/J1 and P/J2 the ROS must be removed from the machine. The ROS PWB may not be marked with the correct PJ numbers, where P/J1 and P/J2 are connected. P/J1 can be identified as a four way power harness. P/J2 can be identified as a seven way signal harness. Check the continuity of the seven way signal harness between P/J2 on the ROS and P/ J2 on the IOT PWB. The harness is good. Y↓N→Install a new ROS power distribution/communication harness, PL 60.10 Item 5. Install a new ROS, PL 60.10 Item 3. If the fault condition persists, perform the following: • Check the condition of the associated wiring and connectors. Repair the wiring or install new components as necessary. • Install a new ROS, PL 60.10 Item 4. • Perform the OF7 IOT PWB Diagnostics RAP.