Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 362B — Xerox WorkCentre 5875

Code: 362B

Description: Side 1 Exposure Lamp Failure RAP The side 1 exposure lamp fails to illuminate. The side 1 exposure lamp does not illuminate consistently throughout the scanning process.
Remedy: Open the SPDH. Enter the dC330 code 062-002, platen exposure lamp. The LED lamp assembly in the scan carriage assembly, illuminates. Y↓N→Go to Flag 4. +24V is available at P/J447 between pin 1 and pin 3, also between pin 2 and pin 4. Y↓N→Go to Flag 1. +24V is available at P/J410 between pins 19 and 20, pins 21 and 22, pins 23 and 24, pins 25 and 26, also pins 27 and 28. Y↓N→+24V is available at P/J140 between pins 19 and 20, pins 21 and 22, pins 23 and 24, pins 25 and 26, also pins 27 and 28. Y↓N→Refer to the 301B 0V Distribution RAP and the 301G +24V Distribution RAP to fix the fault. Check and repair the harness and connectors between P/J140 on the power distribution PWB and P/J410 on the scanner PWB. Go to Flag 1 and Flag 2, disconnect, check and clean if necessary, then reconnect P/J410, P/J416 and P/J446. +24V is now available at P/J447 between pin 1 and pin 3, also between pin 2 and pin 4. Y↓N→Install new components as necessary: • Scan carriage power ribbon cable, PL 60.20 Item 10 • Scanner CCD PWB, PL 60.25 Item 4 • Scanner PWB, PL 60.20 Item 6 Go to Flag 4. +24V is available at P/J448 between pin 6 and pin 4, also between pin 5 and pin 3. Y↓N→Check and repair the wiring and connectors between P/J447 and P/J448. Go to Flag 5, check the wiring and connectors between P/J449 and P/J450. The wiring and connectors are good. Y↓N→Repair the wiring or connectors as necessary.. Go to Flag 3, check both ends of the scan carriage data ribbon cable are clean and securely connected. The ribbon cable connections are good. Y↓N→Clean and reconnect the ribbon cable, if necessary install a new scan carriage data ribbon cable, PL 60.20 Item 17. Install a new scan carriage assembly, PL 60.25 Item 1. Go to Flag 4. +24V is available at P/J448 between pin 6 and pin 4, also between pin 5 and pin 3. Y↓N→Check and repair the wiring and connectors between P/J447 and P/J448.. Go to Flag 5, check the wiring and connectors between P/J449 and P/J450. The wiring and connectors are good. Y↓N→Repair the wiring or connectors as necessary.. Go to Flag 3, check the both ends of the scan carriage data ribbon cable are clean and securely connected. The ribbon cable is good. Y↓N→Clean and reconnect the ribbon cable, if necessary install a new scan carriage data ribbon cable, PL 60.20 Item 17. 1. Install a new scan carriage assembly, PL 60.25 Item 1. 2. Perform ADJ 60.5 IIT Registration, Magnification and Calibration. 3. Perform SCP 5 Final Actions. Go to dC612, make a print of internal test pattern 2. Make a copy of the test pattern print from the document glass. The copy has uneven bands in the cross process direction. Y↓N→Perform SCP 5 Final Actions. Go to Flag 3, check the both ends of the scan carriage data ribbon cable are clean and securely connected. The ribbon cable is good. Y↓N→Clean and reconnect the ribbon cable, if necessary install a new scan carriage data ribbon cable, PL 60.20 Item 17. Install a new scan carriage data ribbon cable, PL 60.20 Item 17.

← Xem tất cả mã lỗi Xerox WorkCentre 5875

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie