Description: Tray 3 Elevator Lift Failure RAP 373-100-00 Tray 3 stack height sensor did not actuate within the correct time after the elevator motor turned on. NOTE: Rapid closure of tray 4 when tray 3 is being elevated may cause this fault.
Remedy: Enter dC330 code 073-300 tray 3 home sensor, Q73-300. Press Start. Pull out tray 3, then push fully home. The display changes. Y↓N→Go to Flag 1. Check S73-300. Refer to: • GP 11 How to Check a Sensor. • P/J1, HCF control PWB. • 301E +5V Distribution RAP. • 301B 0V Distribution RAP Install new components as necessary: • Tray 3 home sensor, PL 70.21 Item 4. • HCF control PWB, PL 70.21 Item 2. Enter dC330 code 073-330 tray 3 stack height sensor, Q73-330. Press Start. Pull out tray 3. Manually activate the stack height sensor on the paper feed assembly. The display changes Y↓N→Go to Flag 2. Check Q73-330. Refer to: • GP 11 How to Check a Sensor. • P/J1, HCF control PWB. • 301E +5V Distribution RAP. • 301B 0V Distribution RAP. Install new components as necessary: • Tray 3 stack height sensor, PL 80.32 Item 7. • HCF control PWB, PL 70.21 Item 2. Disconnect P/J10 on the HCF control PWB. Connect a service meter between pin 1 and pin 2 on the wiring side of the connector. Continuity is measured when the stack limit switch is deactuated and an open circuit is measured when the switch is actuated. Y↓N→Go to Flag 3. Check the tray 3 over elevate switch. Refer to: • GP 13 How to Check a Switch. • P/J10, HCF control PWB. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. Install new components as necessary: • Tray 3 over elevate switch, PL 80.32 Item 8. • HCF control PWB, PL 70.21 Item 2. CAUTION To prevent damage to the elevator and paper feed mechanism, the paper tray must be pulled out before MOT07-030 is run in service mode. Re-connect P/J10. Enter dC330 code 073-010 tray 3 elevator motor, MOT73-010. Pull out tray 3. Press Start. The motor runs. Y↓N→Go to Flag 4. Check MOT73-010. Refer to: • GP 10 How to Check a Motor. • P/J13, HCF control PWB. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP Install new components as necessary: • Tray 3 elevator motor, PL 70.21 Item 1. • HCF control PWB, PL 70.21 Item 2. Perform the following: • Check the elevator cables, PL 70.18 Item 4, PL 70.18 Item 6 and PL 70.18 Item 8. • Check the elevator drives gear coupling, PL 70.19 Item 10. If the fault remains, go to the 373B Tray 3 or Tray 4 Out of Paper RAP.