Description: Duplex Paper Path Jam RAP (65-90 ppm)
Remedy: NOTE: The front door interlock must be cheated when checking +24V components. Enter dC330 code 083-160 duplex sensor, Q83-160. Press Start. Activate Q83-160. The display changes. Y↓N→Go to Flag 1. Check Q83-160. Refer to: • GP 11 How to Check a Sensor. • P/J5, IOT PWB. • 301E +5V Distribution RAP. • 301B 0V Distribution RAP. If necessary install a new duplex sensor, (65-90 ppm) PL 80.20 Item 4. If the problem persists, perform OF7 IOT PWB Diagnostics RAP. Enter dC330 code 083-060 duplex motor slow, MOT83-060. Press Start. MOT83- 060 runs. Y↓N→Go to Flag 2. Check MOT83-060. Refer to: • GP 10 How to Check a Motor. • P/J4, IOT PWB. • P/J50, P/J91, duplex motor driver PWB. • 301G +24V Distribution RAP. • 301E +5V Distribution RAP. • 301B 0V Distribution RAP. Install new components as necessary: • Duplex motor, (65-90 ppm) PL 80.20 Item 8. • Duplex motor driver PWB, (65-90 ppm) PL 80.20 Item 9. If the problem persists, perform OF7 IOT PWB Diagnostics RAP. The transport rolls rotate. Y↓N→Check the drive belt and pulleys, (65-90 ppm) PL 80.20 Item 2 and PL 80.20 Item 10. Enter dC330 code 010-030 inverter motor slow, 10-030. Press Start. MOT10-030 runs. Y↓N→Go to Flag 3. Check MOT10-030. Refer to: • GP 10 How to Check a Motor. • P/J4, IOT PWB. • P/J45, P/J55. • 301G +24V Distribution RAP. • 301E +5V Distribution RAP. • 301B 0V Distribution RAP. Install new components as necessary: • Inverter motor, PL 10.14 Item 13. • Inverter motor driver PWB, PL 10.11 Item 22. If the problem persists, perform OF7 IOT PWB Diagnostics RAP. The transport rolls rotate. Y↓N→Refer to GP 7. Check drive gears, PL 10.15. Enter dC330 code 010-050 inverter nip solenoid, SOL10-050. Press Start. 10-050 energizes. Y↓N→Go to Flag 4. Check SOL10-050. Refer to: • GP 12 How to Check a Solenoid or Clutch. • P/J5, IOT PWB. • P/J17, LVPS. • Fuse, PL 1.10 Item 9, GP 7. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. If necessary install a new inverter nip solenoid, PL 10.11 Item 6. If the problem persists, perform OF7 IOT PWB Diagnostics RAP. Enter dC330 code 010-045 inverter path solenoid, SOL10-045. Press Start. SOL10- 045 energizes. Y↓N→Go to Flag 5. Check SOL10-045. Refer to: • GP 12 How to check a Solenoid or Clutch. • P/J5, IOT PWB. • P/J17, LVPS. • Fuse, PL 1.10 Item 9, GP 7. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. If necessary install a new inverter path solenoid, PL 10.11 Item 14. If the problem persists, perform OF7 IOT PWB Diagnostics RAP. Check the following, refer to GP 7: • Duplex nip rolls, (65-90 ppm) PL 80.20 Item 7. • Nip split shaft assembly, PL 10.11 Item 4. • Idler rolls, PL 10.12 Item 15. • If the fault still occurs, check the drives plate on the registration clutch for damage and contamination. Refer to the replacement procedure.