Description: Erase Lamp Failure RAP 394-350-00 The photoreceptor erase lamp has failed.
Remedy: NOTE: The door interlock switch must be cheated when checking +24V components. Cheat the door interlock switch. Enter dC330 code 091-022, photoreceptor erase lamp. Press start. Observe the erase lamp. All the LEDs of the erase lamp are lit. Y↓N→Some of the LEDs of the erase lamp are lit. Y↓N→Go to Flag 1. +24V is available at P/J17 pin 1 on the LVPS. Y↓N→Perform the 301L LVPS Checkout RAP. Go to Flag 2. +24V is available at P/J41 pin 1. Y↓N→Go to Flag 1. Check the inline fuse. The fuse is good. Y↓N→Install a new fuse, PL 1.10 Item 9. If the fuse blows again, perform the 301G +24V Distribution RAP. Perform the relevant procedure: • Go to 301G +24V Distribution RAP. • 301B 0V Distribution RAP. Go to Flag 3. +13V is available at P/J5 pin 14. Y↓N→NOTE: To gain access to the erase lamp wiring, remove the main drive module, (45-55 ppm) PL 40.15 Item 1 or (65-90 ppm) PL 40.10 Item 1. Check the wiring from the in-line fuse to P/J41, pin 2. The wiring is good. Y↓N→Repair the wiring. Perform the steps that follow: • Check that the connector PJ41 is located correctly in the IOT frame. • Install a new erase lamp, PL 90.20 Item 1. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. Install a new erase lamp, PL 90.20 Item 1. The fault may be intermittent. Perform the steps that follow: • Check the wiring, GP 7 between P/J41 and P/J17 on the LVPS. • Ensure that the P/Js are correctly and securely connected. • Malfunction of the following associated circuits can cause 09-350 faults. – The inverter paper path and Inverter nip solenoid, go to the 310-120-00, 310-121-00, 310-126-00 IOT Exit Sensor RAP. – The vacuum transport fan and registration clutch, go to the 310-101-00A, 310-102- 00A, 310-103-00A Lead Edge Late to Fuser Exit Sensor RAP.