Description: SPDH Lift Home Sensor Failure RAP 305-958-00 The lift home sensor does not sense the home position after the tray elevate motor drives the input tray to the home position.
Remedy: Enter dC330 code 005-390 to run the tray elevator motor, MOT05-390. MOT05-390 runs and cycles the tray between the raised and lowered positions. Y↓N→Remove the SPDH rear cover (5 screws). Remove the sensor bracket, PL 5.18 Item 10. Turn over the bracket to access the lift home position sensor. Enter dC330 code 005-307, lift home position sensor, Q05-307. Actuate the sensor using a piece of paper. The display changes. Y↓N→Go to Flag 1. Check Q05-307. Refer to: • GP 11 How to Check a Sensor • P/J462, SPDH PWB • 301D +3.3V Distribution RAP • 301B 0V Distribution RAP Install new components as necessary: • Lift home position sensor, PL 5.18 Item 9 • SPDH PWB, PL 5.10 Item 5 Enter dC330 code 005-309, doc present sensor, Q05-309. Actuate the sensor using the doc present sensor actuator, PL 5.30 Item 6. The display changes. Y↓N→Go to Flag 3. Check Q05-309. Refer to: • GP 11 How to Check a Sensor • P/J462, SPDH PWB • 301D +3.3V Distribution RAP • 301B 0V Distribution RAP Install new components as necessary: • Doc present sensor, PL 5.30 Item 5 • SPDH PWB, PL 5.10 Item 5 Open the top cover to access the stack height sensor, Q05-310. Enter dC330 code 005-310, stack height sensor, Q05-310. Actuate the sensor using the sensor actuating arm. The display changes. Y↓N→Go to Flag 4. Check Q05-310. Refer to: • GP 11 How to Check a Sensor • P/J465 SPDH PWB • 301D +3.3V Distribution RAP • 301B 0V Distribution RAP Install new components as necessary: • Stack height sensor, PL 5.20 Item 4 • SPDH PWB, PL 5.10 Item 5 Go to Flag 2, check the tray elevator motor MOT05-390. Refer to: • GP 10 How to Check a Motor • P/J469 SPDH PWB • 301G +24V Distribution RAP • 301B 0V Distribution RAP Install new components as necessary: • Tray elevator motor, PL 5.18 Item 3 • SPDH PWB, PL 5.10 Item 5 Check the drive components between the tray elevator motor and the input tray shaft assembly. Install new parts as necessary: • Tray elevator reduction gears, PL 5.19 Item 9 Go to SCP 5 Final actions.