Description: LVF BM Back Stop Failure RAP 311-065-00-150 The back stop motor fails to run. 311-383-00-150 The back stop is not at the home position. 311-484-00-150 The back stop failed to move to the mid home position in the allowed time. 311-486-00-150 The back stop failed to move away from the mid home position in the allowed time.
Remedy: Check the following parts for damage: • BM back stop drive belt. PL 11.80 Item 8. • BM back stop drive pulley. PL 11.80 Item 7. • BM back stop pulleys, PL 11.80 Item 5. • BM back stop belt, PL 11.80 Item 4. • BM back stop assembly, PL 11.82 Item 8. The parts are good, Y↓N→Install new parts as necessary. Enter dC330 code 011-383. Actuate the back stop home sensor, by rotating the drive belt and pulley by hand so that the flag on the back stop moves into and out of the back stop home sensor. The display changes. Y↓N→Go to Flag 1, check the back stop home sensor, Q11-383. Refer to: • GP 11, How to Check a Sensor. • P/J105, LVF BM PWB. • 311D-150 LVF BM Power Distribution RAP. Install new components as necessary: • LVF BM PWB, PL 11.90 Item 1. • Back stop home sensor, PL 11.80 Item 10. Enter dC330 code 011-440. Actuate the back stop mid home sensor, by rotating the drive belt and pulley by hand so that the flag on the back stop moves into and out of the back stop mid home sensor. The display changes. Y↓N→Go to Flag 2, check the back stop mid home sensor, Q11-440. Refer to: • GP 11, How to Check a Sensor. • P/J105, LVF BM PWB. • 311D-150 LVF BM Power Distribution RAP. Install new components as necessary: • LVF BM PWB, PL 11.90 Item 1. • Back stop mid home sensor, PL 11.82 Item 4. Enter dC330 code 011-065 to run the back stop motor, MOT11-065. The motor runs. Y↓N→Go to Flag 3, check the back stop motor, MOT11-065. Refer to: • GP 10, How to Check a Motor. • P/J105, LVF BM PWB. • 311D-150 LVF BM Power Distribution RAP. Install new components as necessary: • LVF BM PWB, PL 11.90 Item 1. • Back stop motor, PL 11.80 Item 9. The fault may be intermittent, check for damaged wiring or connectors. If necessary repair the wiring or install new components.