Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 311-300-00-110, 311-302-00-110, 311-303-00-110 — Xerox WorkCentre 5890

Code: 311-300-00-110, 311-302-00-110, 311-303-00-110

Description: Interlocks RAP 311-300-00-110 The docking interlock is open during run mode. 311-302-00-110 The top cover interlock is open during run mode. 311-303-00-110 The front door interlock is open during run mode.
Remedy: Go to Flag 1. Check for +24V on P/J302 pin 1. If the voltage is not present, refer to the 311D- 110 2K LCSS Power Distribution RAP. Go to the relevant procedure: • 311-300-00-110 Docking Interlock Checkout • 311-302-00-110 Top Cover Interlock Checkout • 311-303-00-110 Front Door Interlock Checkout 311-300-00-110 Docking Interlock Checkout Un-dock the 2K LCSS-110. Check the docking interlock switch, S11-300 as follows: • Check the interlock actuator on the machine is not damaged or missing. NOTE: The wiring harness passes underneath the docking interlock switch housing. If this harness is not correctly positioned, the switch can be mis-located, giving intermittent docking interlock problems. • Enter dC330 code 011-300. Actuate S11-300. If the display does not change, refer to: – GP 13, How to Check a Switch –. – P/J302, 2K LCSS PWB. • Go to Flag 1. Check the wiring between P/J302 and S11-300. • If necessary, install a new docking interlock switch, PL 11.4 Item 2. 311-302-00-110 Top Cover Interlock Checkout Check the top cover interlock switch, S11-302 as follows: • Check the switch actuator. • Enter dC330 code 011-302. Actuate S11-302. If the display does not change, refer to: – GP 13, How to Check a switch –. – P/J315, 2K LCSS PWB. • Go to Flag 3. Check the wiring between P/J315 and S11-302. • If necessary, install a new top cover interlock s witch, PL 11.26 Item 6. 311-303-00-110 Front Door Interlock Checkout Check the front door interlock switch, S11-303 as follows: • Check the switch actuator. • Enter dC330 code 011-303-00. Actuate S11-303. If the display does not change, refer to: – GP 13, How to Check a switch –. – P/J302, 2K LCSS PWB. • Go to Flag 2. Check the wiring between P/J302 and S11-303. • If necessary, install a new front door interlock switch, PL 11.26 Item 5. Perform SCP 5 Final Actions.

← Xem tất cả mã lỗi Xerox WorkCentre 5890

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie