Mã lỗi 311E-150 — Xerox WorkCentre 5890

Code: 311E-150

Description: LVF BM to Machine Communications Interface RAP All communications between the machine and LVF BM are conducted through a single interface cable. A UI message System Error or Finisher Comms Failure may be seen.
Remedy: Observe the software heartbeat LED (LED 1) on the LVF PWB. LED 1 is flashing at 1Hz (0.5 seconds on, 0.5 seconds off). Y↓N→LED 1 is flashing at 0.25Hz (2 seconds on, 2 seconds off) this indicates that the finisher software is corrupt. Re-load the finisher software, GP 4. If necessary install a new LVF PWB, PL 11.90 Item 8. Observe the software heartbeat LED (LED 1) on the LVF BM PWB. LED 1 is flashing at 1Hz (0.5 seconds on, 0.5 seconds off). Y↓N→LED 1 is flashing at 0.25Hz (2 seconds on, 2 seconds off) this indicates that the booklet maker software is corrupt. Re-load the finisher software, GP 4. If necessary install a new LVF BM PWB, PL 11.90 Item 1. Go to Flag 1, check the wiring and connectors between P/J101 and P/J401. The wiring and connectors are good. Y↓N→Repair the wiring or connectors. Go to Flag 2, check the wiring and connectors between P/J301and P/J11. The wiring and connectors are good. Y↓N→Repair the wiring or connectors. The finisher checks are good. Switch off the machine, then switch on the machine, GP 14. If the fault remains, perform the Forced Altboot Software Loading Procedure, GP 4.

← Xem tất cả mã lỗi Xerox WorkCentre 5890

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie