Code: 341-359-00

Description: HCF Communications and Detection Error RAP 341-359-00 The HCF has failed to respond to tray 1 and 2 control PWB ping requests.
Remedy: 1. Ensure the P/Js on the tray 1 and 2 control PWB, PL 70.10 Item 2 and the HCF PWB, PL 70.21 Item 2 are correctly and securely connected. 2. Go to Flag 1. Check the harness. Repair as necessary, GP 7. 3. Go to Flag 1. Check the power supply lines. Refer to: • 301G +24V Distribution RAP. • 301E +5V Distribution RAP. • 301B 0V Distribution RAP. 4. Go to Flag 2. Check for the presence of pulses on the two data lines, using the AC volts range of the meter. NOTE: Pulses should be measured approximately every 20 seconds. Between pulses, the voltage should be approximately 1.5VAC. 5. As necessary, install new components: • Tray 1 and 2 control PWB, PL 70.10 Item 2. • HCF control PWB, PL 70.21 Item 2. 6. Reload the software, GP 4, Machine Software.