Mã lỗi 361-350-00 — Xerox WorkCentre 5890

Code: 361-350-00

Description: ROS Laser Not Under Control RAP 361-350-00 The IOT monitor has not received a reset command from the IOT ROS controller for more than 5 seconds during print.
Remedy: 1. Ensure all the P/Js on the IOT PWB, PL 1.10 Item 2 are correctly and securely connected. 2. Perform the OF7 IOT PWB Diagnostics RAP. 3. Reload the software set, GP 4, Machine Software. NOTE: The supply harness is a flying lead that is a part of the LVPS and is not spared separately. 4. Go to Flag 1. Check the voltages. As necessary, refer to: • 301G +24V Distribution RAP. • 301F +12V Distribution RAP. • 301E +5V Distribution RAP. • 301D +3.3V Distribution RAP. • 301B 0V Distribution RAP. 5. Perform the following as necessary: • OF7 IOT PWB Diagnostics RAP. • 301L LVPS Checkout RAP.