Description: Scanner Calibration Faults RAP 362-450-00 Dark range status bit is not clear prior to calibration. 362-451-00 Dark range status bit is not set after calibration. 362-452-00 Pixel offset status bit is not clear prior to calibration. 362-453-00 Pixel offset status bit is not set after calibration. 362-454-00 Gain range status bit is not clear prior to calibration. 362-455-00 Gain range status bit is not set after calibration. 362-456-00 Pixel gain status bit is not clear prior to calibration. 362-457-00 Pixel gain status bit is not set after calibration. 362-458-00 Highest intensity image pixel value exceeds maximum tolerance. 362-459-00 Pixel offset error (Hi) exceeds maximum adjustment allowed during dark calibration. 362-460-00 Pixel offset error (Lo) exceeds maximum adjustment allowed during dark calibration. 362-461-00 Highest intensity image pixel value is lower than the minimum tolerance. 362-462-00 Pixel gain error (Hi) exceeds maximum adjustment allowed during white calibration. 362-463-00 Pixel gain error (L0) exceeds maximum adjustment allowed during white calibration. 362-464-00 The scanner is requested to perform another operation while busy. 362-466-00 Pixels out of range during black calibration. 362-467-00 Pixels out of range during white calibration. 362-468-00 Pixel clock error from the full width array. 362-469-00 Calibration ASIC comms. error with m/c. 362-470-00 Unable to read the registers in the calibration ASIC. 362-471-00 Calibration ASIC write buffer is full. 362-472-00 Calibration ASIC comms. time-out. 362-781-00 IIT Remote NVM out of range.
Remedy: Perform ADJ 60.5 IIT Registration, Magnification and Calibration. The fault persists. Y↓N→Go to SCP 5 Final Actions. Go to Flag 1, disconnect then check the scan carriage ribbon cable and connectors P/J445 on the scanner CCD BWB and P/J412 on the scanner PWB.. The ribbon cable and connectors are clean and undamaged. Y↓N→Clean or repair the ribbon cable or connectors, if necessary install new components: • Scan carriage data ribbon cable, PL 60.20 Item 17. • Scan carriage assembly, PL 60.20 Item 1. • Scanner PWB, PL 60.20 Item 4. Reconnect the P/J445 to P/J412 scan carriage data ribbon cable. Go to Flag 2, disconnect then check the SBC PWB/Scanner PWB data cable and connectors, P/J411 on the scanner PWB and PJ250 on the SBC PWB. The data cable and connectors are clean and undamaged. Y↓N→Clean or repair the cable connectors. Install new components as necessary: • SBC PWB/Scanner PWB data cable, PL 3.22 Item 20. • Scanner PWB, PL 60.20 Item 4. If the fault remains, perform the 303D SBC PWB Diagnostics RAP. Perform dC301 scanner system NVM initialization, then ADJ 60.5 IIT Registration, Magnification and Calibration. If the problem continues reload the software using the AltBoot Software Loading Procedure, go to GP 4 Machine Software.