Description: Side 2 Exposure Lamp Failure RAP The side 2 exposure lamp fails to illuminate.
Remedy: Refer to. Open the SPDH, then the jam clearance guide. Enter the dC330 code 066- 002, DH exposure lamp. The LED lamp assembly in the side 2 scan assembly illuminates. Y↓N→Go to Flag 5. +24V is available at P/J453 between pin 1 and pin 3, also between pin 2 and pin 4. Y↓N→Go to Flag 1. +24V is available at P/J410 between pins 19 and 20, pins 21 and 22, pins 23 and 24, pins 25 and 26, also pins 27 and 28. Y↓N→+24V is available at P/J140 between pins 19 and 20, pins 21 and 22, pins 23 and 24, pins 25 and 26, also pins 27 and 28. Y↓N→Refer to the 301B 0V Distribution RAP and the 301G +24V Distribution RAP to fix the fault. Check and repair the harness and connectors between P/J410 on the power distribution PWB and P/J140 on the scanner PWB. Go to Flag 1, Flag 2 and Flag 3, disconnect, check and clean if necessary, then reconnect P/J140, P/J418, P/J459, P/J458 and P/J452. +24V is now available at P/J453 between pin 1 and pin 3, also between pin 2 and pin 4. Y↓N→Install new components as necessary: • Side 2 scan assembly power ribbon cable, PL 5.10 Item 6 • Side 2 CCD PWB, PL 60.30 Item 4 • SPDH PWB, PL 5.10 Item 5 • Scanner PWB, PL 60.20 Item 6 Go to Flag 6. +24V is available at P/J454 between pin 1 and pin 3, also between pin 2 and pin 4. Y↓N→Check and repair the wiring and connectors between P/J453 and P/J454. Go to Flag 7 and Flag 8, check the wiring and connectors between P/J454 and P/ J455. The wiring and connectors are good. Y↓N→Repair the wiring or connectors as necessary. Go to Flag 4, check both ends of the side 2 scan assembly data ribbon cable are clean and securely connected. The ribbon cable connections are good. Y↓N→Clean and reconnect the ribbon cable, if necessary, install a new side 2 scan assembly data ribbon cable, PL 5.10 Item 16. Install a new side 2 scan assembly data ribbon cable, PL 5.10 Item 16. Go to Flag 6. +24V is available at P/J454 between pin 1 and pin 3, also between pin 2 and pin 4. Y↓N→Check and repair the wiring and connectors between P/J453 and P/J454. Go to Flag 7 and Flag 8, check the wiring and connectors between P/J454 and P/J455. The wiring and connectors are good. Y↓N→Repair the wiring or connectors as necessary. Go to Flag 4, check both ends of the side 2 scan assembly data ribbon cable are clean and securely connected. The ribbon cable connections are good. Y↓N→Clean and reconnect the ribbon cable, if necessary, install a side 2 scan assembly data ribbon cable PL 5.10 Item 16. 1. Install a new side 2 scan assembly data ribbon cable, PL 5.10 Item 16. 2. Perform ADJ 60.5 IIT Registration, Magnification and Calibration. 3. Perform SCP 5 Final Actions. Perform SCP 5 Final Actions.