Code: 391-375-00

Description: Ambient Temperature Sensor Failure RAP 391-375-00 The average ambient temperature is out of limits.
Remedy: Enter dC330 code 042-602, ambient temperature sensor, Q42-602. Press start. Observe the displayed state of Q42-602.. Open the bypass tray and left door assembly, PL 70.30 Item 1, gently blow on the temperature sensor PWB. Observe again the displayed state of Q42-602. The displayed state has changed. Y↓N→Go to Flag 1. Check for +5V at P/J7 pin 3 on the IOT PWB. +5V is present. Y↓N→Go to: • 301E +5V Distribution RAP. • 301B 0V Distribution RAP. Go to Flag 1. Disconnect P/J46. Check for +5V at P/J46, pin 1. +5V is present. Y↓N→Check the wiring between P/J7 on the IOT PWB and P/J46. Repair the wiring as necessary. Install a new humidity sensor/ambient temperature sensor, PL 90.20 Item 4. If the fault remains, perform the OF7 IOT PWB Diagnostics RAP. The ambient temperature sensor is working correctly. If the fault is intermittent, perform the steps that follow: • Check the wiring, GP 7. Repair as necessary. • Make sure that the P/Js are correctly and securely connected, GP 11.