Mã lỗi 394-370-00 — Xerox WorkCentre 5890

Code: 394-370-00

Description: Developer Temperature Sensor Failure RAP 394-370-00 The average developer temperature reading is out of limits.
Remedy: Enter dC140 code 092-602, developer temperature sensor Q92-602. Press start. Observe the displayed state of Q92-602. Remove the xerographic module. Disconnect P/J47. Cheat the front door interlock. Observe again the displayed state of Q92-602. The displayed state has changed. Y↓N→Go to Flag 1. Check for +5V at P/J7 pin 5 on the IOT PWB. +5V is present. Y↓N→Go to: • 301E +5V Distribution RAP. • 301B 0V Distribution RAP. Go to Flag 1. Check for +5V at P/J47 pin 3. +5V is present. Y↓N→NOTE: To gain access to the wiring, remove the main drive module, (45-55 ppm) PL 40.15 Item 1 or (65-90 ppm) PL 40.10 Item 1 and the left cover, PL 28.10 Item 3. Check the wiring between P/J7 on the IOT PWB and P/J47. Repair the wiring as necessary. Install a new developer temperature sensor, PL 90.20 Item 5. If the fault remains perform the OF7 IOT PWB Diagnostics RAP. Q92-602 is working correctly. Reconnect P/J47. If the fault is intermittent, perform the steps that follow: • Check the wiring, GP 7. Repair if necessary. • Make sure that the P/Js are correctly and securely connected.