Description: Lead Edge Late to Post Fuser Sensor 310-153-00 The lead edge of the paper failed to actuate the post fuser sensor within the correct time for a simplex sheet. 310-163-00 The lead edge of the paper failed to actuate the post fuser sensor within the correct time for a duplex sheet.
Remedy: NOTE: Ensure that the door interlock switches are cheated when checking +24V components. Open the left door. Enter dC330 code 010-120, post fuser sensor, Q10-120. Use a piece of paper to actuate Q10-120. The display changes. Y↓N→Go to Flag 1. Check Q10-120. Refer to: • GP 11, How to Check a Sensor. • P/J761, IOT PWB. • 301E +5V and +5VSB Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new post fuser sensor, PL 10.11 Item 7. If the fault persists, perform OF7 IOT PWB Diagnostics RAP. Enter dC330 code 010-020, fuser drive motor, MOT10-020. Observe the fuser roll and the pressure roll through the top of the fuser. The fuser rolls turn. Y↓N→Go to Flag 2. Check MOT10-020. Refer to: • GP 10, How to Check a Motor. • P/J761, IOT PWB. • P/J656, LVPS. • 301E +5V and +5VSB Distribution RAP. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new main drive module, PL 40.15 Item 1. If the fault persists, perform OF7 IOT PWB Diagnostics RAP and 301L LVPS RAP. Enter dC330 code 093-045, print cartridge motor, MOT93-045. Observe the photoreceptor. The photoreceptor turns. Y↓N→Go to Flag 2. Check MOT93-045. Refer to: • GP 10, How to check a Motor. • P/J761, IOT PWB. • P/J656, LVPS. • 301E +5V and +5VSB Distribution RAP. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. Install new components as necessary: • Main drive module, PL 40.15 Item 1. • Print cartridge, PL 90.17 Item 9. If the fault persists, perform OF7 IOT PWB Diagnostics RAP and 301L LVPS RAP. Enter dC330 code 080-040, registration motor, MOT80-040. Observe the registration roll, PL 80.17 Item 5. The registration roll turns. Y↓N→Go to Flag 3. Check MOT80-040. Refer to: • GP 10, How to Check a Motor. • P/J762, IOT PWB. If necessary, install a new registration motor, PL 40.15 Item 6. If the fault persists, perform OF7 IOT PWB Diagnostics RAP. The jam occurs when feeding sheets from the bypass tray. Y↓N→Refer to GP 7 and OF10 Intermittent Fault RAP. Check the components that follow: • Registration idler roll, PL 80.15 Item 4. • Bias transfer roll, PL 80.15 Item 3. • Registration roll, PL 80.17 Item 6. • Registration drive gear, PL 80.17 Item 3. • Track (DTS), PL 90.10 Item 6, from the detack saw to the HVPS. If the fault persists, perform the 381A Paper Feed Retries RAP. Perform the 381-155-00 Lead Edge Late to Registration Sensor from the Bypass Tray RAP.