Mã lỗi 310-320-00 — Xerox WorkCentre 5945

Code: 310-320-00

Description: Fuser Control Failure RAP 310-320-00 One or more fuser lamps is above the maximum temperature, or the temperature difference between any of the lamps is greater than 25 degrees C.
Remedy: Switch off, then switch on the machine, GP 14. The display shows ‘Ready to Copy’. Y↓N→Go to Flag 1. The voltage at the front and mid fuser temperature sensors should be 3.2 volts when the sensors are cold. In standby mode the voltage should be 0.72 to 0.96 volts. Refer to: • P/J764, IOT PWB. • PJ100. • 301D +3.3V Distribution RAP. • 301B 0V Distribution RAP. Before new components are installed, restore the NVM values to default. As necessary, perform the actions that follow: • Repair the harness between P/J764 and PJ100. • Install a new fuser connector, PL 10.8 Item 3. • Perform the OF7 IOT PWB Diagnostics RAP. If the fault persists, install a new fuser module, PL 10.8 Item 1. Perform SCP 5 Final Actions.