Description: Offset Motor Fault RAP 310-702-00 The offset shuttle failed to return to the home position.
Remedy: Enter dC330 code 010-300, offset sensor, Q10-300. Move the offset shuttle slowly backwards and forwards. The display changes. Y↓N→Go to Flag 1. Check Q10-300. Refer to: • GP 11, How to Check a Sensor. • P/J761, IOT PWB. • 301E +5V and +5VSB Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new offset sensor, PL 10.11 Item 8. If the fault persists, perform OF7 IOT PWB Diagnostics RAP. Remove the centre output tray. Enter dC330 code 010-500, offset motor forward or code 010-501, offset motor reverse, MOT10-500. The motor operates. Y↓N→Go to Flag 2. Check MOT10-500. Refer to: • GP 10, How to Check a Motor. • P/J770, IOT PWB. If necessary, install a new offset motor, PL 10.11 Item 14. If the fault persists, perform OF7 IOT PWB Diagnostics RAP. Refer to GP 7. Check the components that follow: • Offset shuttle, PL 10.11 Item 22. • Inverter assembly, PL 10.10 Item 1.