Description: Sheet Late to Bin 1 RAP 312-151-00-110 The compile exit sensor was not deactuated within a specified time. 312-152-00-110 The compile exit sensor was not actuated within a specified time
Remedy: NOTE: All 2K LCSS interlocks must be made to supply +24V to the motors. Enter dC330 code 012-224 to run the transport motor 2, MOT12-224. The motor runs. Y↓N→Go to Flag 3. Check MOT12-224. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 10, How to check a motor. • P/J309, 2K LCSS PWB. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Transport motor 2, PL 12.60 Item 5. • 2K LCSS PWB, PL 12.75 Item 1. Enter dC330 code 012-225 to energize the exit diverter solenoid, SOL12-225. The solenoid energizes. Y↓N→Go to Flag 4. Check SOL12-225. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 12, How to Check a Solenoid or Clutch. • P/J306, 2K LCSS PWB. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Exit diverter solenoid, PL 12.60 Item 12. • 2K LCSS PWB, PL 12.75 Item 1. Enter dC330 code 012-106, compiler exit sensor, Q12-106. Actuate Q12-106. The display changes. Y↓N→Go to Flag 1. Check Q12-106. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 11, How to Check a sensor. • P/J313, 2K LCSS PWB. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Compiler exit sensor, PL 12.65 Item 4. • 2K LCSS PWB, PL 12.75 Item 1. Enter dC330, code 012-223 to run the transport motor 1, MOT12-223. The motor runs. Y↓N→Go to Flag 2. Check MOT12-223. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 10, How to Check a Motor. • P/J305, 2K LCSS PWB. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Transport motor 1, PL 12.40 Item 2. • 2K LCSS PWB, PL 12.75 Item 1. If the fault persists, perform the procedures that follow: • 312-396-00-110, 312-397-00-110, 312-398-00-110 Rear Tamper Move Failure RAP • 312H-110 Copy Damage in the 2K LCSS RAP • 312J-110 Mis-Registration in Stapled Sets and Non-Stapled Sets RAP.