Description: Paper Exiting to Bin 0 RAP 312-171-00-150 The leading edge of the sheet was late to the top exit sensor. 312-172-100-150 The trailing edge of the sheet was late from the top exit sensor.
Remedy: NOTE: All LVF BM interlocks must be made to supply +24V to the motors. Enter dC330, code 012-224 to run transport motor 2, MOT12-224. The motor runs. Y↓N→Go to Flag 3. Check MOT12-224. Refer to: • GP 10, How to Check a Motor. • P/J309, LVF PWB. • 312D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Transport motor 2, PL 12.370 Item 5. • LVF PWB, PL 12.425 Item 8. Enter dC330, code 012-225 to energize the exit diverter solenoid, SOL12-225. The solenoid energizes. Y↓N→Go to Flag 2. Check SOL12-225. Refer to: • GP 12, How to Check a Solenoid. • P/J306, LVF PWB. • 312D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Exit diverter solenoid, PL 12.370 Item 12. • LVF PWB, PL 12.425 Item 8. Enter dC330, code 012-107, top tray exit sensor, Q12-107. Actuate Q12-107. The display changes. Y↓N→Go to Flag 1. Check Q12-107. Refer to: • GP 11, How to Check a Sensor. • P/J314, LVF PWB. • 312D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Top tray exit sensor, PL 12.370 Item 11. • LVF PWB, PL 12.425 Item 8. Enter dC330, code 012-223 to run the transport motor 1, MOT12-223. The motor runs. Y↓N→Go to Flag 4. Check MOT12-223. Refer to: • GP 10, How to Check a Motor. • P/J305, LVF PWB. • 312D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Transport motor 1, PL 12.350 Item 2. • LVF PWB, PL 12.425 Item 8. Perform SCP 5 Final Actions.