Code: 312-340-00-110, 312-341-00-110, 312-342-00-110
Description: Ejector Movement Failure RAP 312-340-00-110 The ejector failed to return to the home position in the required time. 312-341-00-110 The ejector failed to move away from the home position in the required time. 312-342-00-110 The ejector failed to attain the compile/eject position in the required time. NOTE: A cycle of operation for the ejector is to cycle from the home position to the out position and back to the home position.
Remedy: NOTE: All 2K LCSS interlocks must be made to supply +24V to the motors. Enter dC330 code 012-185, ejector out sensor Q12-185. Actuate Q12-185. The display changes. Y↓N→Go to Flag 2. Check Q12-185. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. • P/J304, 2K LCSS PWB. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Ejector out sensor, PL 12.50 Item 3. • 2K LCSS PWB, PL 12.75 Item 1. Enter dC330 code 012-184, ejector home sensor Q12-184. Actuate Q12-184. The display changes. Y↓N→Go to Flag 1. Check Q12-184. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. • P/J304, 2K LCSS PWB. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Ejector home sensor, PL 12.50 Item 3. • 2K LCSS PWB, PL 12.75 Item 1. Enter dC330 code 012-236, ejector motor cycle to cycle the ejector motor, MOT12-234. The ejector cycles between the out position and the home position. Y↓N→Check that the large tie-wrap around the motor of the ejector assembly has not cut through the motor wires and caused a short circuit to the case of the motor. The wiring is good. Y↓N→Cut the tie-wrap, then insulate the wires. Go to Flag 3. Check MOT12-234. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 10, How to Check a Motor. • P/J303, 2K LCSS PWB. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Ejector assembly, PL 12.50 Item 1. • 2K LCSS PWB, PL 12.75 Item 1. The ejector cycles noisily, colliding with the end stops. Y↓N→Check the stapler to ensure the staples are correctly formed. Mis-formed staples can cause the set to hang in the stapler causing ejector movement failures. The staples are correctly formed. Y↓N→Clear the staple head of any mis-formed staples, then check the operation of the stapler. If necessary, install a new staple head unit, PL 12.55 Item 5. If the ejector is still not moving, install a new ejector assembly, PL 12.50 Item 1. Enter dC330 code 012-096, ejector motor encoder sensor Q12-096. Slowly rotate the ejector motor encoder wheel. The display changes. Y↓N→Go to Flag 4. Check Q12-096. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. • P/J304, 2K LCSS PWB. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Ejector motor encoder sensor, PL 12.50 Item 3. • 2K LCSS PWB, PL 12.75 Item 1. Perform the 312G-110 2K LCSS PWB Damage RAP. If necessary install a new 2K LCSS PWB, PL 12.75 Item 1.