Description: Front Tamper Move Failure RAP 312-392-00-110 The front tamper failed to move from the home position in the required time. 312-393-00-110 The front tamper failed to return to the home position in the required time. 312-394-00-110 The front tamper failed to return to the away home position in the required
Remedy: NOTE: All 2K LCSS interlocks must be made to supply +24V to the motors. Enter dC330 codes 012-226, front tamper motor home and 012-228, front tamper motor move alternately. The front tamper moves between the home and away positions. Y↓N→Go to Flag 2. Check the front tamper motor, MOT12-226. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 10 How to Check a Motor. • P/J312, 2K LCSS PWB. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Tamper assembly, PL 12.45 Item 1. • 2K LCSS PWB, PL 12.75 Item 1. Enter dC330 code 012-180, front tamper home sensor, Q12-180. Actuate Q12-180. The display changes. Y↓N→Go to Flag 1. Check Q12-180. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. • P/J312, 2K LCSS PWB. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Tamper assembly, PL 12.45 Item 1. • 2K LCSS PWB, PL 12.75 Item 1. NOTE: The front tamper home sensor is bonded onto the tamper unit and is not replaceable. Therefore, failure of this sensor will require the replacement of the tamper assembly. Enter dC330 code 012-182, front tamper away sensor, Q12-182. Actuate Q12-182. The display changes. Y↓N→Go to Flag 3. Check Q12-182. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 11, How to Check a Sensor. • P/J314, 2K LCSS PWB. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Front tamper away sensor, PL 12.45 Item 1. • 2K LCSS PWB, PL 12.75 Item 1. Perform SCP 5 Final Actions.