Code: 312-462-00-110
Description: Bin 1 Movement Failure RAP 312-462-00-110 Bin 1 failed to leave the bin 1 upper level sensor during stacking or failed to initialize correctly. NOTE: The home position of bin 1 is when the bin is just lower than the bin 1 upper level sensor. See the final actions at the end of the procedure. Two sensors and 2 switches monitor the level of paper in bin 1 and the position of the tray: • The bin 1 upper level sensor, detects the top of the paper stack in bin 1, or the empty bin 1, PL 12.35 Item 3. • The bin 1 90% full sensor, detects when the tray has descended to a position where the tray is 90% full, PL 12.30 Item 5. • Bin 1 upper limit switch, prevents over travel, PL 12.30 Item 3. • Bin 1 lower limit switch, prevents over travel, PL 12.35 Item 1.
Remedy: NOTE: All 2K LCSS interlocks must be made to supply +24V to the motors. Remove the 2K LCSS rear cover. Enter dC330 code 012-163, bin 1 motor encoder sensor Q12-163, PL 12.30 Item 11. Slowly rotate the encoder disk by hand. The display changes. Y↓N→Go to Flag 2. Check Q12-163. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. • P/J304, 2K LCSS PWB. •, Component location. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Bin 1 motor encoder sensor Q12-163, PL 12.30 Item 5. • 2K LCSS PWB, PL 12.75 Item 1. Enter dC330 code 012-242. Bin 1 cycles down and up. Y↓N→Go to Flag 1. Check the bin 1 elevator motor, MOT12-241, PL 12.30 Item 8. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 10 How to Check a Motor. • P/J318, 2K LCSS PWB. •, Component location. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Bin 1 elevator motor, PL 12.30 Item 8. • 2K LCSS PWB, PL 12.75 Item 1. Enter dC330 code 012-188, actuate the bin 1 upper level sensor, Q12-188, PL 12.35 Item 3. The display changes. Y↓N→Go to Flag 3. Check Q12-188. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. • P/J314, 2K LCSS PWB. •, Component location. • 312D-110 2K LCSS Power Distribution RAP. •-110 2K LCSS Un-docking. Install new components as necessary: • Bin 1 upper level sensor, PL 12.35 Item 3. • 2K LCSS PWB, PL 12.75 Item 1. Enter dC330 code 012-190, actuate the bin 1 upper limit switch, S12-190, PL 12.30 Item 3. The display changes. Y↓N→Go to Flag 4. Check S12-190. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 13 How to Check a Switch. • P/J315, 2K LCSS PWB. •, Component location. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Bin 1 upper limit switch, PL 12.30 Item 3. • 2K LCSS PWB, PL 12.75 Item 1. Enter dC330 code 012-191, actuate the bin 1 lower limit switch, S12-191, PL 12.35 Item 1. The display changes. Y↓N→Go to Flag 5. Check S12-191. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 13 How to Check a Switch. • P/J317, 2K LCSS PWB. •, Component location. • 312D-110 2K LCSS Power Generation RAP. •-110 2K LCSS Un-docking. Install new components as necessary: • Bin 1 lower limit switch, PL 12.35 Item 1. • 2K LCSS PWB, PL 12.75 Item 1. Enter dC330 code 012-187. Actuate the bin 1 90% full sensor, Q12-187, PL 12.30 Item 5. The display changes. Y↓N→Go to Flag 6. Check Q12-187. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. • P/J316, 2K LCSS PWB. •, Component location. • 312D-110, 2K LCSS Power Distribution RAP. Install new components as necessary: • Bin 1 90% full sensor, PL 12.30 Item 5. • 2K LCSS PWB, PL 12.75 Item 1. As final actions, check the sequence of operation that follows: • Paper is delivered to the tray until the bin 1 upper level sensor, Q12-188 is actuated. • The bin 1 elevator motor MOT12-241 lowers the tray until the bin 1 upper level sensor, Q12-188 is de-actuated. • The Bin 1 elevator motor raises the tray until the top of the paper stack actuates the Bin 1 upper level sensor, then the Bin 1 elevator motor lowers the tray to continue the cycle. • When the tray is emptied, the tray returns to the home position. The tray is elevated until the bin 1 upper level sensor, Q12-188 is made. The tray is then lowered until the bin 1 upper level sensor, Q12-188 is just cleared. In the home position the bin 1 upper limit switch, S12-190 is actuated.