Description: LED Print Head Data Integrity Failure RAP 361-100-00 Checksum read from LED print head did not match the checksum calculated on the SBC PWB.
Remedy: Perform dC304 LED Print head Validation. The LED print head validation test failed. Y↓N→Perform SCP 5 Final Actions. Switch off, then switch on the machine, GP 14. The fault persists. Y↓N→Perform SCP 5 Final Actions. Go to Flag 1. Disconnect, then check the ribbon cable and connectors, P/J511 on the LED print head module and P/J851 on the SBC PWB. The ribbon cable and connectors are clean and undamaged. Y↓N→Clean or repair the ribbon cable and connectors. Install new components as necessary: • LED print head to SBC PWB ribbon cable, PL 60.35 Item 17. • LED print head module, PL 60.35 Item 1. Re-install the ribbon cable. Perform dC304 LED Print Head Validation. The LED print head validation test failed. Y↓N→Perform SCP 5 Final Actions. Install a new LED print head module, PL 60.35 Item 1. Check the operation of the machine. The fault persists. Y↓N→Perform SCP 5 Final Actions. Reload the software, GP 4. If the fault persists, perform the 303D SBC PWB Diagnostics RAP.