Code: 366A
Description: Side 2 LED Exposure Lamp Failure RAP The side 2 LED exposure lamp failed to illuminate.
Remedy: Refer to. Open the SPDH, then the jam clearance guide. Enter the dC330 code 066- 002, DH exposure lamp. The LED lamp assembly in the side 2 scan assembly illuminates. Y↓N→Go to Flag 5. +24V is available at P/J453 between pin 1 and pin 3, and between pin 2 and pin 4. Y↓N→Go to Flag 1. +24V is available at P/J410 between pins 19 and 20, between pins 21 and 22, between pins 23 and 24, and between pins 25 and 26. Y↓N→+24V is available at P/J861 between pins 7 and 8, between pins 5 and 6, between pins 3 and 4, and between pins 1 and 2. Y↓N→Check the power supply. Refer to: • 301B 0V Distribution RAP. • 301G +24V Distribution RAP. Check the SBC PWB/scanner PWB comms/power harness, PL 60.20 Item 5. Check P/J861 on the SBC PWB and P/J410 on the Scanner PWB. Repair as necessary. Go to Flag 1, Flag 2 and Flag 3. Disconnect, check and clean if necessary, then reconnect P/J410, P/J418, P/J459, P/J458 and P/J452. +24V is now available at P/J453 between pin 1 and pin 3, and between pin 2 and pin 4. Y↓N→Install new components as necessary: • Side 2 scan assembly power ribbon cable, PL 5.10 Item 6. • Side 2 CCD PWB, PL 60.30 Item 4. • SPDH PWB, PL 5.10 Item 5. • Scanner PWB, PL 60.20 Item 4. Go to Flag 6. +24V is available at P/J454 between pin 1 and pin 3, and between pin 2 and pin 4. Y↓N→Check the wiring and connectors between P/J453 and P/J454. Repair as necessary. Go to Flag 7 and Flag 8. Check the wiring and connectors between P/J454 and P/ J455. The wiring and connectors are good. Y↓N→Repair the wiring or connectors as necessary. . Go to Flag 4. Check that both ends of the side 2 scan assembly data ribbon cable are clean and securely connected. The ribbon cable connections are good. Y↓N→Clean and reconnect the ribbon cable. If necessary, install a new side 2 scan assembly data ribbon cable, PL 5.10 Item 16. Install a new side 2 scan assembly data ribbon cable, PL 5.10 Item 16. Go to Flag 6. +24V is available at P/J454 between pin 1 and pin 3, and between pin 2 and pin 4. Y↓N→Check the wiring and connectors between P/J453 and P/J454. Repair as necessary. Go to Flag 7 and Flag 8. Check the wiring and connectors between P/J454 and P/J455. The wiring and connectors are good. Y↓N→Repair the wiring or connectors as necessary. . Go to Flag 4. Check that both ends of the side 2 scan assembly data ribbon cable are clean and securely connected. The ribbon cable connections are good. Y↓N→Clean and reconnect the ribbon cable. If necessary, install a side 2 scan assembly data ribbon cable PL 5.10 Item 16. Perform the steps that follow: 1. Install a new side 2 scan assembly data ribbon cable, PL 5.10 Item 16. 2. ADJ 60.3 IIT Registration, Magnification and Calibration. 3. SCP 5 Final Actions. Perform SCP 5 Final Actions.