Description: Bypass Tray Lift Failure RAP 375-100-00 The bypass tray elevate sensor failed to actuate within the correct time.
Remedy: Enter dC330 code 075-040, bypass tray elevate sensor, Q75-040. Manually actuate the sensor. The display changes. Y↓N→Go to Flag 1. Check Q75-040. Refer to: • GP 11 How to Check a Sensor. • P/J750, IOT PWB. • 301E +5V and +5VSB Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new bypass tray elevate sensor, PL 70.35 Item 20. If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. With the left door closed, enter dC330 code 080-025, TAR/bypass tray motor, MOT80-006, PL 80.25 Item 5. The motor runs in reverse. Y↓N→Go to Flag 2. Check MOT80-006. Refer to: • GP 10, How to Check a Motor. • P/J754, IOT PWB. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new TAR/bypass tray motor, PL 80.25 Item 5. If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. Go to Flag 3. Check the bypass tray clutch. Refer to: • GP 12 How to Check a Solenoid or Clutch. • P/J757, IOT PWB. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. The clutch is good. Y↓N→If necessary, install a new bypass tray clutch, PL 70.35 Item 9. If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. Check the condition and operation of the components that follow. Refer to GP 7 Miscellaneous Checks: • Bypass tray drive assembly. • Tension spring. • Bypass tray drive belt, PL 80.25 Item 10. • Drive pulley, PL 80.25 Item 3. • Bypass tray lift plate shaft, cam, cam follower and cam drive gear. Install new components as necessary: • Bypass tray assembly, PL 70.35 Item 1. • Bypass tray drive belt, PL 80.25 Item 10. • Drive pulley, PL 80.25 Item 3.