Description: Humidity Sensor Failure RAP 391-365-00 Average humidity reading was out of limits. Also use this RAP if the humidity sensor is suspected of working incorrectly. A faulty relative humidity sensor can cause image quality problems.
Remedy: Remove trays 1 and 2. Remove the tray 1 paper feed assembly. Enter dC140 code 091-601, humidity sensor, Q91-601. Observe the displayed state of Q91-601. Use an air duster, PL 26.11 Item 1 directed onto the environmental sensors PWB to change the state of Q91-601. The displayed state changed. Y↓N→Go to Flag 1. Check for +5V at P/J763 pin 16 on the IOT PWB. +5V is present. Y↓N→Go to: • 301E +5V and +5VSB Distribution RAP. • 301B 0V Distribution RAP. Go to Flag 1. Disconnect PJ982. Check for +5V at PJ982, pin 12. +5V is present. Y↓N→Check the wiring between P/J763 on the IOT PWB and PJ982. Repair the wiring as necessary. Install a new environmental sensors PWB, PL 80.17 Item 8. If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. If possible, check the humidity of the external environment using a hygrometer. Compare with a reading from Q91-601. Refer to the NOTE above Table 1. If a hygrometer is not available refer to Table 1 for the approximate expected humidity value. Compare the expected values with Q91-601. If the value of Q91-601 is very different from the expected reading install a new environmental sensors PWB, PL 80.17 Item 8. If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. If the fault is intermittent, perform the steps that follow: • Check the wiring, GP 7. Repair as necessary. • Ensure that the P/Js are correctly and securely connected. NOTE: The actual value is not critical. If the reading from Q91-601 is approximately within the range indicated in column 4, Table 1, the sensor is good. External Environment Average Relative Humidity Cold Machine Relative Humidity Warm Machine Relative Humidity Wet 80% 80% 40% to 50% Ambient 50% 50% 15% to 30% Dry 10% 10% 1% to 7%