Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 393-360-00 ... 393-364-00 — Xerox WorkCentre 5945

Code: 393-360-00 ... 393-364-00

Description: Toner Concentration Sensor Failure RAP 393-360-00 The toner concentration sensor registered a reading outside the expected range. 393-361-00 The toner concentration sensor was reading high. This indicates that the toner concentration (TC) was low. 393-362-00 The toner concentration sensor was reading low. This indicates that the toner concentration (TC) was high. 393-364-00 The toner concentration sensor registered a reading outside the range.
Remedy: NOTE: At completion of this procedure, perform the NVM Check. NOTE: The front door and left door interlock switches must be cheated when checking +24V components. NOTE: If the machine fails to run while performing a check in this procedure, enter dC131 location 501-359 SystemLockoutFault. Set the value to 0. Enter dC330 093-045, to run the print cartridge motor, MOT93-045. Go to Flag 1. Check the voltage at P/J766 pin 1. The voltage is outside the range of +1V to +2V. Y↓N→The fault may be intermittent. Perform the steps that follow: • Check the wiring between PJ510 and PJ766 on the IOT PWB. Refer to GP 7. • Check the 0V distribution. Refer to the 301B 0V Distribution RAP. • Ensure the print cartridge is correctly installed. • If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. The voltage at P/J766 pin 1 is less than +1V. Y↓N→The voltage is greater than +2V. Perform the TC Increase Adjustment. The increase was successful. Y↓N→Go to Flag 2. +5V is present at P/J766, pin 2. Y↓N→Go to: • 301E +5V and +5VSB Distribution RAP. • 301B 0V Distribution RAP. Go to Flag 3. 0V is available at P/J766, pin 3. Y↓N→Go to the 301B 0V Distribution RAP. Enter dC330, code 093-045, print cartridge motor. Add the code 093-040, toner cartridge motor. NOTE: The routine 93-040 times out after 5 seconds. The toner cartridge rotates. Y↓N→Remove the toner cartridge, PL 90.17 Item 2. Enter dC330, code 093-040, toner cartridge motor, MOT93-040. The motor runs. Y↓N→Go to Flag 4. Check MOT93-040. Refer to: • GP 10 How to Check a Motor. • P/J767, IOT PWB. • 301G +24V Generation and Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new toner dispense module, PL 90.17 Item 1. If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. Check the toner dispense drive gears. If necessary, install a new toner dispense module, PL 90.17 Item 1. Remove the print cartridge, PL 90.17 Item 9, then place in a black bag. Remove the fuser, PL 10.10 Item 1. Put a sheet of paper beneath the toner dispense tube. Enter dC330, code 093-040, toner cartridge motor, MOT93-040. Manually open the shutter on the toner dispense tube. Toner is dispensed. Y↓N→Ensure the shutter on the toner dispense tube opens and closes correctly. If necessary, install a new toner dispense module, PL 90.17 Item 1. Ensure the shutter on the print cartridge, opens and closes correctly. If necessary, install a new print cartridge, PL 90.17 Item 9. The fault may be intermittent. Perform the steps that follow: • Check the wiring between PJ510 and PJ766 on the IOT PWB. Refer to GP 7. • Check the 0V distribution. Refer to the 301B 0V Distribution RAP. • Ensure the print cartridge is correctly installed. • If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. Go to Flag 2. +5V is present at P/J766, pin 2. Y↓N→Go to: • 301E +5V and +5VSB Distribution RAP. • 301B 0V Distribution RAP. Go to Flag 3. 0V is available at P/J766, pin 3. Y↓N→Go to the 301B 0V Distribution RAP. Perform the TC Reduction Adjustment. The reduction was successful. Y↓N→Install a new print cartridge, PL 90.17 Item 9. The fault may be intermittent. Perform the steps that follow: • Check the wiring between PJ510 and PL766 on the IOT PWB. Refer to GP 7. • Check the 0V distribution. Refer to the 301B 0V Distribution RAP. • Ensure the print cartridge is correctly installed. • If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. TC Reduction Adjustment Perform the steps that follow: 1. Enter dC131 location 501-230 TCHighCdEnable. Set the value 0. 2. Disconnect P/J512. Refer to. 3. Open the SPDH. Make 10 copies. 4. Go to Flag 1. Monitor the voltage output. 5. Make sets of 10 copies until the monitored voltage is greater than 0.9V. 6. Check the image quality. 7. Reconnect P/J512. 8. Re-enter dC131 location 501-230 TCHighCdEnable. Set the value 1. TC Increase Adjustment Perform the steps that follow: 1. Enter dC330 code 093-045, print cartridge motor. Add the code 093-040, toner cartridge motor. 2. Go to Flag 1. Monitor the voltage output. 3. Run the routine until the monitored voltage is between 2.2V and 2.8V. 4. Check the image quality. Refer to IQS 1 Solid Area Density and Tone Reproduction. NVM Check Enter dC131, ensure the NVM locations that follow are set as listed: • 501-223 TcFailCyDnEn, set to 1. • 501-229 TCLowCdEnable, set to 1. • 501-230 TCHighCdEnable, set to 1. • 501-359 SystemLockoutFault, set to 0.

← Xem tất cả mã lỗi Xerox WorkCentre 5945

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie