Description: Front Door Open RAP 301-300-00 The front door has opened during machine operation.
Remedy: Enter dC330, code 001-300, front door interlock. Open and close the front door. The display changes. Y↓N→Use an interlock cheater to actuate the front door interlock switch, SO1-300. The display changes. Y↓N→Go to Flag 1. Check S01-300. Refer to: • P/J763, IOT PWB. • GP 13 How to Check a Switch. • Wiring Harness Repairs. If necessary install a new front door interlock switch, PL 1.12 Item 1. If the fault persists, perform OF7 IOT PWB Diagnostics RAP. Check that the front door, PL 28.10 Item 5 closes correctly. If not, check the components that follow: • The toner dispense latch is in the latched position, PL 90.17 Item 5. • The LED print head module latch is in the latched position, PL 60.35 Item 2. • The switch actuating flag on the front door for damage, if necessary install a new front door assembly, PL 28.11 Item 1. Check the components that follow: • The switch actuating flag on the front door for damage. • The front door assembly, PL 28.11 Item 1 is not distorted or damaged. • The magnet, PL 28.11 Item 3 is not damaged or missing. If necessary install a new front door assembly, PL 28.11 Item 1.