Code: 310-154-00, 310-164-00
Description: Trail Edge Late from Post Fuser Sensor RAP 310-154-00 The trail edge of the paper failed to de-actuate the post fuser sensor within the correct time for a simplex sheet. 310-164-00 The trail edge of the paper failed to de-actuate the post fuser sensor within the correct time for a duplex sheet.
Remedy: NOTE: Ensure that the door interlock switches are cheated when checking +24V components. Open the left door. Enter dC330 code 010-120, post fuser sensor, Q10-120. Use a piece of paper to actuate Q10-120. The display changes. Y↓N→Go to Flag 1. Check Q10-120. Refer to: • GP 11, How to Check a Sensor. • P/J761, IOT PWB. • 301E +5V and +5VSB Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new post fuser sensor, PL 10.11 Item 7. If the fault persists, perform OF7 IOT PWB Diagnostics RAP. Enter dC330 code 010-020, fuser drive motor, MOT10-020. Observe the fuser roll and the pressure roll through the top of the fuser. The fuser rolls turn. Y↓N→Go to Flag 2. Check MOT10-020. Refer to: • GP 10, How to Check a Motor. • P/J761, IOT PWB. • P/J656, LVPS. • 301E +5V and +5VSB Distribution RAP. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. Install new components as necessary: • Main drive module, PL 40.15 Item 1. • Fuser module, PL 10.8 Item 1. If the fault persists, perform OF7 IOT PWB Diagnostics RAP and 301L LVPS RAP. Enter dC330 code 010-020, MOT10-020. Observe the exit roll and exit drive gears. The motor runs and drives the exit drive roll. Y↓N→Check the components that follow: • Exit drive assembly, PL 10.14 Item 1. • Exit drive belts, PL 10.14 Item 2 and PL 10.14 Item 3. • Inverter assembly, PL 10.10 Item 1. Enter dC330 code 010-045, inverter gate solenoid, SOL10-045. Observe the solenoid and inverter gate. The solenoid energizes and the inverter gate is pulled down. Y↓N→Go to Flag 3. Check SOL10-045. Refer to: • GP 12 How to Check a Solenoid or Clutch. • P/J762, IOT PWB. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new inverter gate solenoid, PL 10.13 Item 8. If the fault persists, perform OF7 IOT PWB Diagnostics RAP. Remove the centre exit cover. Enter dC330 code 010-030, inverter motor forward, MOT10-030, PL 10.12 Item 8. The motor runs and turns the inverter drive roll. Y↓N→Go to Flag 4. Check MOT10-030. Refer to: • GP 10, How to Check a Motor. • P/J762, IOT PWB. Install new components as necessary: • Inverter motor, PL 10.11 Item 9 (centre output tray) or PL 10.12 Item 8 (horizontal transport). • Drive belt, PL 10.11 Item 4 (centre output tray) or PL 10.12 Item 4 (horizontal transport). If the fault persists, perform OF7 IOT PWB Diagnostics RAP. Refer to GP 7. Check the components that follow: • Post fuser roll, PL 80.22 Item 12. • Horizontal transport assembly, PL 10.15 Item 1. • Inverter assembly, PL 10.10 Item 1. If the fault persists, perform the 381A Paper Feed Retries RAP.