Mã lỗi 310-170-00 — Xerox WorkCentre 5955

Code: 310-170-00

Description: Lead Edge Late to Horizontal Transport Entry Sensor RAP 310-170-00 The lead edge of the paper failed to actuate the horizontal transport entry sensor within the correct time.
Remedy: NOTE: Ensure that the door interlock switches are cheated when checking +24V components. Open the horizontal transport top cover. Enter dC330 code 010-041, horizontal transport entry sensor, Q10-041, PL 10.15 Item 8. Use a piece of paper to actuate Q10-041. The display changes. Y↓N→Go to Flag 1. Check Q10-041. Refer to: • GP 11, How to Check a Sensor. • P/J773, IOT PWB. • 301E +5V and +5VSB Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new horizontal transport entry sensor, PL 10.15 Item 8. If the fault persists, perform OF7 IOT PWB Diagnostics RAP. Open the left door. Enter dC330 code 010-020, fuser drive motor, MOT10-020. Observe the fuser roll and pressure roll through the top of the fuser. The fuser rolls turn. Y↓N→Go to Flag 2. Check MOT10-020. Refer to: • GP 10, How to Check a Motor. • P/J773, IOT PWB. • P/J656, LVPS. • 301E +5V and +5VSB Distribution RAP. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new main drive module, PL 40.15 Item 1. If the fault persists, perform OF7 IOT PWB Diagnostics RAP and 301L LVPS RAP. Enter dC330 code 010-020, MOT010-020. Observe the exit roll and exit drive gears. The motor runs and turns the exit drive roll. Y↓N→Check the components that follow: • Exit drive assembly, PL 10.14 Item 1. • Exit drive belts, PL 10.14 Item 2 and PL 10.14 Item 3. • Inverter assembly, PL 10.10 Item 1. Enter dC330 code 010-045, inverter gate solenoid, SOL10-045. Observe the solenoid and inverter gate. The solenoid energizes and the inverter gate is pulled down. Y↓N→Go to Flag 3. Check SOL10-045. Refer to: • GP 12 How to Check a Solenoid or Clutch. • P/J762, IOT PWB. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new inverter gate solenoid, PL 10.13 Item 8. If the fault persists, perform OF7 IOT PWB Diagnostics RAP. Refer to GP 7. Check the components that follow: • Post fuser roll, PL 80.22 Item 12. • Inverter assembly, PL 10.10 Item 1. If the fault persists, perform the 381A Paper Feed Retries RAP.

← Xem tất cả mã lỗi Xerox WorkCentre 5955

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie