Code: 312-340-00-150, 312-342-00-150
Description: Ejector Movement Failure RAP 312-340-00-150 The ejector was not at the home position. 312-342-00-150 The ejector failed to perform a cycle of operation. NOTE: A cycle of operation for the ejector is to cycle from the home position to the out position and back to the home position.
Remedy: NOTE: All LVF BM interlocks must be made to supply +24V to the motors. Enter dC330, code 012-185, ejector out sensor, Q12-185. Actuate Q12-185. The display changes. Y↓N→Go to Flag 2. Check Q12-185. Refer to: • GP 11 How to Check a Sensor. •. • P/J304, LVF PWB. • 312D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Ejector out sensor, PL 12.360 Item 3. • LVF PWB, PL 12.425 Item 8. Enter dC330, code 012-184, ejector home sensor, Q12-184. Actuate Q12-184. The display changes. Y↓N→Go to Flag 1. Check Q12-184. Refer to: • GP 11 How to Check a Sensor. •. • P/J304, LVF PWB. • 312D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Ejector home sensor, PL 12.360 Item 3. • LVF PWB, PL 12.425 Item 8. Enter dC330, code 012-236, ejector motor cycle. Check the operation of the ejector motor, MOT12-234. The motor runs. Y↓N→Go to Flag 3. Check MOT12-234. Refer to: • GP 10, How to Check a Motor. •. • P/J303, LVF PWB. • 312D-150 LVF BM Power Distribution RAP. Repair or Install new components as necessary: • Ejector assembly, PL 12.360 Item 1. • LVF PWB, PL 12.425 Item 8. Enter dC330, code 012-236, ejector motor cycle. Check the ejector cycles. Add the code 12- 184, ejector sensor home, Q12-184. Then cycle the ejector. Add the code 12-185, ejector out sensor, Q12-185. Then cycle the ejector. The ejector actuates the ejector home sensor and the ejector out sensor. Y↓N→Refer to GP 7, check the components that follow, install new components as necessary; • Pulley drive gear, PL 12.360 Item 8. • Ejector belt, PL 12.360 Item 5. The ejector cycles noisily, colliding with the end stops. Y↓N→Check the stapler to ensure the staples are correctly formed. Mis-formed staples can cause the set to hang in the stapler causing ejector movement failures. The staples are correctly formed. Y↓N→Clear the staple head of any mis-formed staples. Then check the operation of the stapler. If necessary, install a new staple head unit, PL 12.365 Item 5. If the ejector is still not moving, install a new ejector assembly, PL 12.360 Item 1. Perform SCP 5 Final Actions. Enter dC330, code 012-096, ejector motor encoder sensor, Q12-096. Actuate Q12-096. The display changes. Y↓N→Go to Flag 4. Check Q12-096. Refer to: • GP 11 How to Check a Sensor. •. • P/J304, LVF PWB. • 312D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • Ejector motor encoder sensor, Q12-096, PL 12.360 Item 3. • LVF PWB, PL 12.425 Item 8. Perform SCP 5 Final Actions.