Description: Stapling Failure RAP 312-377-00-150 Staples in the staple head unit were not primed.
Remedy: Enter dC330, code 012-196, SH1 paper sensor, Q12-196. Actuate Q12-196. The display changes. Y↓N→Go to Flag 1. Check Q12-196. Refer to: •. • GP 11, How to Check a Sensor. • P/J308, LVF PWB. • 312D-150 LVF BM Power Distribution RAP. Repair or install new components as necessary: • SH1 paper sensor, PL 12.365 Item 4. • LVF PWB, PL 12.425 Item 8. NOTE: If the SH1 priming sensor does not see staples in the primed position, the staple head cycles a number of times to prime the staple head. This occurs when the LVF BM interlocks are made. Follow the customer instruction label inside the LVF BM front door to remove the staple cartridge. Slide out the top sheet of staples from the cartridge to expose a new sheet of staples on the top of the stack. Ensure the forming plate is fully closed. Install the staple cartridge and close the door. The stapler will now cycle a few times to feed and prime the new sheet of staples. Open the door and remove the staple cartridge. Examine the sheet of staples that have been fed to the staple forming part of the stapler by opening the forming plate. The first 2 staples have been partially formed. Y↓N→Install a new staple cartridge, PL 12.365 Item 7 and repeat the check. If the first 2 staples are not partially formed, install a new staple head unit, PL 12.365 Item 5. Perform SCP 5 Final Actions. Install a new staple head unit, PL 12.365 Item 5. Perform SCP 5 Final Actions.