Mã lỗi 312-462-00-110 — Xerox WorkCentre 5955

Code: 312-462-00-110

Description: Bin 1 Movement Failure RAP 312-462-00-110 Bin 1 failed to leave the bin 1 upper level sensor during stacking or failed to initialize correctly. NOTE: The home position of bin 1 is when the bin is just lower than the bin 1 upper level sensor. See the final actions at the end of the procedure. Two sensors and 2 switches monitor the level of paper in bin 1 and the position of the tray: • The bin 1 upper level sensor, detects the top of the paper stack in bin 1, or the empty bin 1, PL 12.35 Item 3. • The bin 1 90% full sensor, detects when the tray has descended to a position where the tray is 90% full, PL 12.30 Item 5. • Bin 1 upper limit switch, prevents over travel, PL 12.30 Item 3. • Bin 1 lower limit switch, prevents over travel, PL 12.35 Item 1.
Remedy: NOTE: All 2K LCSS interlocks must be made to supply +24V to the motors. Remove the 2K LCSS rear cover. Enter dC330 code 012-163, bin 1 motor encoder sensor Q12-163, PL 12.30 Item 11. Slowly rotate the encoder disk by hand. The display changes. Y↓N→Go to Flag 2. Check Q12-163. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. • P/J304, 2K LCSS PWB. •, Component location. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Bin 1 motor encoder sensor Q12-163, PL 12.30 Item 5. • 2K LCSS PWB, PL 12.75 Item 1. Enter dC330 code 012-242. Bin 1 cycles down and up. Y↓N→Go to Flag 1. Check the bin 1 elevator motor, MOT12-241, PL 12.30 Item 8. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 10 How to Check a Motor. • P/J318, 2K LCSS PWB. •, Component location. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Bin 1 elevator motor, PL 12.30 Item 8. • 2K LCSS PWB, PL 12.75 Item 1. Enter dC330 code 012-188, actuate the bin 1 upper level sensor, Q12-188, PL 12.35 Item 3. The display changes. Y↓N→Go to Flag 3. Check Q12-188. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. • P/J314, 2K LCSS PWB. •, Component location. • 312D-110 2K LCSS Power Distribution RAP. •-110 2K LCSS Un-docking. Install new components as necessary: • Bin 1 upper level sensor, PL 12.35 Item 3. • 2K LCSS PWB, PL 12.75 Item 1. Enter dC330 code 012-190, actuate the bin 1 upper limit switch, S12-190, PL 12.30 Item 3. The display changes. Y↓N→Go to Flag 4. Check S12-190. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 13 How to Check a Switch. • P/J315, 2K LCSS PWB. •, Component location. • 312D-110 2K LCSS Power Distribution RAP. Install new components as necessary: • Bin 1 upper limit switch, PL 12.30 Item 3. • 2K LCSS PWB, PL 12.75 Item 1. Enter dC330 code 012-191, actuate the bin 1 lower limit switch, S12-191, PL 12.35 Item 1. The display changes. Y↓N→Go to Flag 5. Check S12-191. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 13 How to Check a Switch. • P/J317, 2K LCSS PWB. •, Component location. • 312D-110 2K LCSS Power Generation RAP. •-110 2K LCSS Un-docking. Install new components as necessary: • Bin 1 lower limit switch, PL 12.35 Item 1. • 2K LCSS PWB, PL 12.75 Item 1. Enter dC330 code 012-187. Actuate the bin 1 90% full sensor, Q12-187, PL 12.30 Item 5. The display changes. Y↓N→Go to Flag 6. Check Q12-187. Refer to: • 312G-110 2K LCSS PWB Damage RAP. • GP 11 How to Check a Sensor. • P/J316, 2K LCSS PWB. •, Component location. • 312D-110, 2K LCSS Power Distribution RAP. Install new components as necessary: • Bin 1 90% full sensor, PL 12.30 Item 5. • 2K LCSS PWB, PL 12.75 Item 1. As final actions, check the sequence of operation that follows: • Paper is delivered to the tray until the bin 1 upper level sensor, Q12-188 is actuated. • The bin 1 elevator motor MOT12-241 lowers the tray until the bin 1 upper level sensor, Q12-188 is de-actuated. • The Bin 1 elevator motor raises the tray until the top of the paper stack actuates the Bin 1 upper level sensor, then the Bin 1 elevator motor lowers the tray to continue the cycle. • When the tray is emptied, the tray returns to the home position. The tray is elevated until the bin 1 upper level sensor, Q12-188 is made. The tray is then lowered until the bin 1 upper level sensor, Q12-188 is just cleared. In the home position the bin 1 upper limit switch, S12-190 is actuated.

← Xem tất cả mã lỗi Xerox WorkCentre 5955

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie