Mã lỗi 362B — Xerox WorkCentre 5955

Code: 362B

Description: Side 1 LED Exposure Lamp Failure RAP The side 1 LED exposure lamp failed to illuminate. The side 1 LED exposure lamp failed to illuminate consistently throughout the scanning process.
Remedy: Open the SPDH. Enter the dC330 code 062-002, platen exposure lamp. The LED lamp assembly in the scan carriage assembly illuminates. Y↓N→Go to Flag 4. +24V is available at P/J447 between pin 1 and pin 3, and between pin 2 and pin 4. Y↓N→Go to Flag 1. +24V is available at P/J410 between pins 19 and 20, between pins 21 and 22, and between pins 23 and 24. Y↓N→+24V is available at P/J861 between pins 7 and 8, between pins 5 and 6, between pins 3 and 4, and between pins 1 and 2. Y↓N→Check the power supply. Refer to: • 301B 0V Distribution RAP. • 301G +24V Distribution RAP. Check the SBC PWB/scanner PWB comms/power harness, PL 60.20 Item 5. Also check the connectors P/J861 on the SBC PWB and P/J410 on the Scanner PWB. Repair as necessary. Go to Flag 1 and Flag 2. Check and clean if necessary, then reconnect P/J410, P/ J416 and P/J446. +24V is now available at P/J447 between pin 1 and pin 3, and between pin 2 and pin 4. Y↓N→Install new components as necessary: • Scan carriage power ribbon cable, PL 60.20 Item 10. • Scanner CCD PWB, PL 60.25 Item 4. • Scanner PWB, PL 60.20 Item 4. Go to Flag 4. +24V is available at P/J448 between pin 6 and pin 4, and between pin 5 and pin 3. Y↓N→Check the wiring and connectors between P/J447 and P/J448. Repair as necessary. Go to Flag 5. Check the wiring and connectors between P/J449 and P/J450. The wiring and connectors are good. Y↓N→Repair the wiring or connectors as necessary. Go to Flag 3. Check that both ends of the scan carriage data ribbon cable are clean and securely connected. The scan carriage data ribbon cable connections are good. Y↓N→Clean and reconnect or if necessary, install a new scan carriage data ribbon cable, PL 60.20 Item 17. Install a new scan carriage assembly, PL 60.25 Item 1. Go to Flag 4. +24V is available at P/J448 between pin 6 and pin 4, and between pin 5 and pin 3. Y↓N→Check the wiring and connectors between P/J447 and P/J448. Repair as necessary. Go to Flag 5. Check the wiring and connectors between P/J449 and P/J450. The wiring and connectors are good. Y↓N→Repair the wiring or connectors as necessary. . Go to Flag 3. Check that both ends of the scan carriage data ribbon cable are clean and securely connected. The scan carriage data ribbon cable is good. Y↓N→Clean and reconnect or if necessary, install a new scan carriage data ribbon cable, PL 60.20 Item 17. Perform the steps that follow: 1. Install a new scan carriage assembly, PL 60.25 Item 1. 2. ADJ 60.3 IIT Registration, Magnification and Calibration. 3. SCP 5 Final Actions. Go to dC612. Make a print of internal test pattern 2 (ITP 3 25% halftone (106dpi 45deg)). Make a copy of the test pattern print from the document glass. The copy has uneven bands in the cross process direction. Y↓N→Perform SCP 5 Final Actions. Go to Flag 3. Check that both ends of the scan carriage data ribbon cable are clean and securely connected. The scan carriage data ribbon cable is good. Y↓N→Clean and reconnect or if necessary, install a new scan carriage data ribbon cable, PL 60.20 Item 17. Install a new scan carriage data ribbon cable, PL 60.20 Item 17.

← Xem tất cả mã lỗi Xerox WorkCentre 5955

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie