Mã lỗi 366-450-00 ... 366-463-00, 366-466-00 ... 366-468-00 — Xerox WorkCentre 5955

Code: 366-450-00 ... 366-463-00, 366-466-00 ... 366-468-00

Description: SPDH Side 2 Scanner Calibration Faults RAP 366-450-00 Dark range status bit was not clear prior to calibration. 366-451-00 Dark range status bit was not set after calibration. 366-452-00 Pixel offset status bit was not clear prior to calibration. 366-453-00 Pixel offset status bit was not set after calibration. 366-454-00 Gain range status bit was not clear prior to calibration. 366-455-00 Gain range status bit was not set after calibration. 366-456-00 Pixel gain status bit was not clear prior to calibration. 366-457-00 Pixel gain status bit was not set after calibration. 366-458-00 Highest Intensity image pixel value exceeded maximum tolerance. 366-459-00 Pixel error exceeded maximum adjustment allowed during dark calibration. 366-460-00 Pixel error exceeded maximum adjustment allowed during dark calibration. 366-461-00 Highest Intensity image pixel value was lower than the minimum tolerance. 366-462-00 Pixel error exceeded maximum adjustment allowed during white calibration. 366-463-00 Pixel error exceeded maximum adjustment allowed during white calibration. 366-466-00 Pixels out range during black calibration. 366-467-00 Pixels out range during white calibration. 366-468-00 Pixel clock error from the full width array.
Remedy: Certain components in this product are susceptible to damage from electrostatic discharge. Observe all ESD procedures to avoid component damage. Perform ADJ 60.3 IIT Registration, Magnification and Calibration. The fault persists. Y↓N→Perform SCP 5 Final Actions. Go to Flag 1. Disconnect, then check the side 2 scan assembly data ribbon cable, PL 5.10 Item 16, and connectors P/J451 on the Side 2 CCD PWB and P/J413 on the Scanner PWB. The side 2 scan assembly data ribbon cable and the connectors are clean and undamaged. Y↓N→Clean or repair the side 2 scan assembly data ribbon cable or connectors. If necessary install new components: • Side 2 scan assembly data ribbon cable, PL 5.10 Item 16. • Side 2 scan assembly, PL 5.10 Item 12. • Scanner PWB, PL 60.20 Item 4. Reconnect the P/J451 to P/J413 side 2 scan assembly data ribbon cable. Go to Flag 2. Disconnect then check the SBC PWB/scanner PWB data cable, PL 60.20 Item 22. Check the connectors P/J411 on the Scanner PWB and P/J854 on the SBC PWB. The SBC PWB/scanner PWB data cable and the P/J connectors are clean and undamaged. Y↓N→Clean or repair the SBC PWB/scanner PWB data cable or connectors. If necessary, install a new scanner PWB, PL 60.20 Item 4. If the fault persists, perform the 303D SBC PWB Diagnostics RAP. Perform dC301 scanner system NVM initialization, then ADJ 60.3 IIT Registration, Magnification and Calibration. If the fault persists, perform an AltBoot, GP 4.

← Xem tất cả mã lỗi Xerox WorkCentre 5955

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie