Description: Tray 1 Elevator Lift Failure RAP 371-100-00 Tray 1 stack height sensor failed to actuate within the correct time after the feed/ elevator motor turned on. 371-217-00 Tray 1 failed to elevate during printing as sheets were fed from the tray.
Remedy: Enter dC330 code 071-330, tray 1 stack height sensor, Q71-330. Pull out tray 1, then push tray 1 fully home. The display changes. Y↓N→Go to Flag 1. Check Q71-330. Refer to: • GP 11 How to Check a Sensor. • P/J751, IOT PWB. • 301E +5V and +5VSB Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new tray 1 stack height sensor, PL 80.26 Item 8. If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. CAUTION To prevent damage to the elevator and paper feed mechanism, the paper tray must be pulled out before MOT07-010 is run in service mode. Enter dC330 code 071-010, tray 1 elevator motor, MOT71-010. Pull out tray 1. The motor runs. Y↓N→Go to Flag 2. Check MOT71-010. Refer to: • GP 10 How to Check a Motor. • P/J752, IOT PWB. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new tray 1 elevator motor, PL 80.26 Item 6. If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. Check the components that follow: • Elevator motor drive gears. • Tray 1 stack height mechanism on the feeder assembly. If the fault persists, perform the 371A Tray 1 and Tray 2 Empty RAP.

← Xem tất cả mã lỗi Xerox WorkCentre 5955

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie