Code: 374-100-00, 374-217-00
Description: Tray 4 Elevator Lift Failure RAP 374-100-00 Tray 4 stack height sensor failed to actuate within the correct time after the elevator motor turned on. 374-217-00 Tray 4 failed to elevate during printing as sheets were fed from the tray. NOTE: Rapid closure of tray 3 when tray 4 is being elevated may cause this fault.
Remedy: Enter dC330 code 074-300, tray 4 home sensor, Q74-300. Pull out tray 4, then push tray 4 fully home. The display changes. Y↓N→Go to Flag 1. Check Q74-300. Refer to: • GP 11 How to Check a Sensor. • GP 30 Tray 4 Control PWB Test Points. • P/J157, Tray 4 control PWB. • P/J775, IOT PWB. • 301E +5V and +5VSB Distribution RAP. • 301B 0V Distribution RAP. Install new components as necessary: • Tray 4 home sensor, PL 70.21 Item 4. • Tray 4 control PWB, PL 70.21 Item 2. Enter dC330 code 074-330, tray 4 stack height sensor, Q74-330. Pull out tray 4. Manually actuate Q74-330. The display changes. Y↓N→Go to Flag 2. Check Q74-330. Refer to: • GP 11 How to Check a Sensor. • GP 30 Tray 4 Control PWB Test Points. • P/J157, Tray 4 control PWB. • P/J775, IOT PWB. • 301E +5V and +5VSB Distribution RAP. • 301B 0V Distribution RAP. Install new components as necessary: • Tray 4 stack height sensor, PL 80.33 Item 7. • Tray 4 control PWB, PL 70.21 Item 2. (W/O TAG 004 Only). Disconnect P/J159 on the Tray 4 control PWB. Connect a service meter between pin 1 and pin 2 on the wiring side of the connector. Continuity is measured when the stack limit switch is deactuated and open circuit is measured when the switch is actuated. Y↓N→Go to Flag 3. Check the tray 4 over elevate switch. Refer to: • GP 13 How to Check a Switch. • GP 30 Tray 4 Control PWB Test Points. • P/J159, Tray 4 control PWB. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. Install new components as necessary: • Tray 4 over elevate switch, PL 80.33 Item 8. • Tray 4 control PWB, PL 70.21 Item 2. CAUTION To prevent damage to the elevator and paper feed mechanism, the appropriate paper tray must be pulled out before MOT74-010 or MOT73-010 is run in service mode. Pull out tray 4. Enter dC330 code 074-010, tray 4 elevator motor, MOT74-010. The motor runs. Y↓N→Pull out tray 3. Enter dC330 code 073-010, tray 3 elevator motor, MOT73-010. The motor runs. Y↓N→Perform the 373-100-00, 373-217-00 Tray 3 Elevator Lift Failure RAP. Perform the steps that follow: • Remove the tray 4 elevator motor. • Remove the tray 3 elevator motor, PL 70.21 Item 1. • Install the tray 3 elevator motor in place of the tray 4 elevator motor. Enter dC330 code 074-010, MOT74-010. The motor runs. Y↓N→Go to Flag 4. Check the wiring between the LVPS and tray 4 control PWB. Refer to: • GP 30 Tray 4 Control PWB Test Points. • P/J158, Tray 4 control PWB. • P/J656, LVPS. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. The wiring is good. Y↓N→Repair the wiring. +24V is present at P/J158 pin 1. Y↓N→If necessary, install a new tray 4 control PWB, PL 70.21 Item 2. If the fault persists, perform the 301L LVPS RAP. Go to Flag 5. Check the wiring between the IOT PWB and tray 4 control PWB. Refer to: • GP 30 Tray 4 Control PWB Test Points. • P/J775, IOT PWB. • P/J155, Tray 4 control PWB. • 301E +5V and +5VSB Distribution RAP. • 301B 0V Distribution RAP. The wiring is good. Y↓N→Repair the wiring. +5V is present at P/J155 pin 11. Y↓N→Perform OF7 IOT PWB Diagnostics RAP. Install a new tray 4 control PWB, PL 70.21 Item 2. Install a new tray 4 elevator motor, PL 70.21 Item 1. Check the components that follow: • The elevator cables, PL 70.19 Item 3, PL 70.19 Item 4 and PL 70.19 Item 5. • The elevator drives gear coupling, PL 70.19 Item 16. If the fault persists, perform the 374B Tray 4 Out of Paper RAP.