Mã lỗi 375A — Xerox WorkCentre 5955

Code: 375A

Description: Bypass Tray RAP Use this RAP to identify and correct problems when using the bypass tray.
Remedy: Enter dC330 code 075-320, bypass tray empty sensor, Q75-320. Manually actuate the sensor. The display changes. Y↓N→Go to Flag 2. Check Q75-320. Refer to: • GP 11 How to Check a Sensor. • P/J750, IOT PWB. • 301E +5V and +5VSB Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new bypass tray empty sensor, PL 70.35 Item 5. If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. Enter dC140 code 075-601, bypass tray width sensor, Q75-601. Move the bypass tray width guides between wide and narrow settings. NOTE: The width sensor is a potentiometer. The wiper of the potentiometer is attached to the bypass tray side guides. This gives a variable voltage to indicate the paper width setting. The display changes. Y↓N→Go to Flag 1. Check Q75-601. Refer to: • GP 11 How to Check a Sensor. • P/J750, IOT PWB. • 301D +3.3V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new bypass tray assembly, PL 70.35 Item 1. If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. Perform the steps that follow: • Ensure that the customer is not filling the tray above the max fill line. • For feeding problems from the bypass tray, perform the 381-155-00 Lead Edge Late to Registration Sensor from Bypass Tray RAP.

← Xem tất cả mã lỗi Xerox WorkCentre 5955

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie