Description: Lead Edge Late to TAR 1 Sensor from Tray 3 RAP 381-195-00 The lead edge of the paper failed to actuate the tray 1 TAR sensor within the correct time after feeding paper from tray 3.
Remedy: NOTE: The front door and left door must be closed, or their respective interlock switches must be cheated when checking +24V components. Enter dC330 code 081-001, tray 1 TAR sensor, Q81-001.. Open the left door. Manually actuate Q81-001. The display changes. Y↓N→Go to Flag 1. Check Q81-001. Refer to: • GP 11 How to Check a Sensor. • P/J750, IOT PWB. • 301E +5V and +5VSB Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new Tray 1 TAR sensor, PL 80.10 Item 5. If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. Enter dC330 code 082-001, tray 2 TAR sensor, Q82-001. Manually actuate Q82-001. The display changes. Y↓N→Go to Flag 2. Check Q82-001. Refer to: • GP 11 How to Check a Sensor. • P/J750, IOT PWB. • 301E +5V and +5VSB Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new Tray 2 TAR sensor, PL 80.10 Item 5. If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. Enter dC330 code 080-006 TAR/bypass tray motor MOT80-006. The motor runs. Y↓N→Go to Flag 3. Check MOT80-006. Refer to: • GP 10 How to Check a Motor. • P/J754, IOT PWB. • 301G +24V Distribution RAP. • 301B 0V Distribution RAP. If necessary, install a new TAR/bypass tray motor, PL 80.25 Item 5. If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. Observe the transport rolls, PL 80.25 Item 7. The transport rolls rotate. Y↓N→Check the transport roll drive belt, drive pulley and pulley, PL 80.25. Install new components as necessary: • Transport roll drive belt, PL 80.25 Item 2. • Pulley, PL 80.25 Item 4. • Transport roll bearing, PL 80.25 Item 6. • Transport roll, PL 80.25 Item 7. If the fault persists perform the 381-159-00 Late to HCF Exit Sensor from Tray 3 RAP.