Mã lỗi 391-375-00 — Xerox WorkCentre 5955

Code: 391-375-00

Description: Ambient Temperature Sensor Failure RAP 391-375-00 The average ambient temperature was out of limits.
Remedy: Remove trays 1 and 2. Remove the tray 1 paper feed assembly. Enter dC140 code 091-602, ambient temperature sensor, Q91-602. Observe the displayed state of Q91-602. Use an air duster, PL 26.11 Item 1 directed onto the environmental sensors PWB to change the state of Q91-602. The displayed state changed. Y↓N→Go to Flag 1. Check for +5V at P/J763 pin 16 on the IOT PWB. +5V is present. Y↓N→Go to: • 301E +5V Distribution RAP. • 301B 0V Distribution RAP. Go to Flag 1. Disconnect PJ982. Check for +5V at PJ982, pin 12. +5V is present. Y↓N→Check the wiring between P/J763 on the IOT PWB and PJ982. Repair the wiring as necessary. Install a new environmental sensors PWB, PL 80.17 Item 8. If the fault persists, perform the OF7 IOT PWB Diagnostics RAP. The ambient temperature sensor is working correctly. If the fault is intermittent, check the wiring, GP 7. Repair as necessary.