Mã lỗi 075-100 — Xerox WorkCentre 6027 MFP

Code: 075-100

Description: Jam Errors The Registration Sensor is not turned ON within the specified time.
Causes: • Feed Roller, PL22.4 • Feed Solenoid, PL6.1.10 • Registration Sensor, PL2.3.5 • Main Drive Assembly, PL6.1.2 • Registration Clutch, PL2.3.7 • Harness Assembly RKN SNS, PL2.2.25 • MCU Board, PL7.2.2
Remedy: 1. Are the Feed Roller and Separator Pad installed correctly? Go to step 2. Install parts that are not correctly installed. 2. Does the Feed Roller rotate smoothly and the tray lift so that the paper contacts the feed roller? Go to step 3. Go to step 7. 3. Does the paper feed to the nip point of the registration roller? Go to step 4. Replace the feed and or separator rollers. 4. Enter diagnostic mode and run the Regi Sensor test (see page 2-136). You can also use CE Diag Tool to perform this test (see page 2-110). Lift the Main Paper Tray Chute (PL3.3.3), this pushes on the actuator, does the number on the display change each time the Main Paper Tray Chute is lifted? Go to step 5. Go to step 6. 5. Disconnect the MCU Board P/J21 and the Registration Sensor P/J120. Check the Harness Assembly RKN SNS for continuity. Is the harness damaged? Go to step 6. Repair or replace the harness. 6. Disconnect the MCU Board P/J21. Is the voltage across ground and P/J12-1 +3.3VDC? Replace the Registration Sensor. 1. SaveNVM to ESS. 2. Replace the MCU Board. 3. LoadNVM from ESS. 7. Enter diagnostic mode and run Main Motor on Full (see page 2-123). You can also use the CE Diag Tool to run this test see "CE Diags Tool". Does the Main Drive Assembly function correctly. Go to step 8 Go to step 10 8. Enter diagnostic mode and run the Feed SOLENOID test. You can also use the CE Diag Tool to run this test see "CE Diags Tool". Does the Feed Solenoid function correctly? Go to step 9. Replace the Feed Solenoid. 9. Enter diagnostic mode and select Engine Diag > Motor Test > Regi Clutch. You can also use the CE Diag Tool to run this test see "CE Diags Tool". Does the Registration Clutch function correctly? 1. SaveNVM to ESS. 2. Replace the MCU Board. 3. LoadNVM from ESS. Replace the Registration Clutch. 10. Check the connector of P/J19 on the MCU Board. Is the connection secure? Go to step 11. Reconnect the connector, then go to step 15. 11. Does the error persist? Go to step 12. Complete. 12. Disconnect P/J16 from the MCU Board and P/J160 from the Main Drive Assembly. Check the continuity of the cable. Is the cable damaged? Repair the cable. Go to step 13. 13. Disconnect the MCU Board P/J16 and check that the voltages across ground at P/J16-2 and P/J16-4 are +24 VDC. Are the voltages correct? Replace the Main Drive Assembly. 1. SaveNVM to ESS 2. Replace the MCU Board. 3. LoadNVM from ESS

← Xem tất cả mã lỗi Xerox WorkCentre 6027 MFP

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie