Mã lỗi 072-216 — Xerox WorkCentre 6505

Code: 072-216

Description: Option Feeder Motor Failure
Causes: • Motor Subassembly (PL12.2.98) • Feeder Board (PL12.2.1) • Tray Motor Harness Assy (PL12.2.2) • Optional Feeder (PL12.1.99)
Remedy: 1 Does the error still occur when the power is turned Off and On? Go to step 2. Complete. 2 Check the connectors of the Motor Subassembly for connection. Check the connections between the Feeder Board and Motor Subassembly. Are P/J422 and P/J4221 connected correctly? Go to step 4. Reconnect the connector(s) P/ J422 and/or P/ J4221 correctly, then go to step 3. 3 Does the error still occur when the power is turned Off and On? Go to step 4. Complete. 4 Check the Tray Motor Harness Assy for continuity. Disconnect J422 from the Feeder Board. Disconnect J4221 from the Motor Subassembly. Is each cable of J422 <=> J4221 continuous? Go to step 5. Replace the Tray Motor Harness Assy. 5 Check after resetting the Motor Subassembly. Reseat the Motor Subassembly. Does the error still occur when the power is turned Off and On? Replace the Optional Feeder. Complete.