Remedy: 1 Does the error still occur when the power is turned Off and On? Go to step 2. Complete. 2 Check the Imaging Unit type. Is the correct Imaging Unit installed? Go to step 4. Replace the Imaging Unit, then go to step 3. 3 Does the error still occur when the power is turned Off and On? Go to step 4. Complete. 4 Reseat the Imaging Unit. Does the error still occur when the power is turned Off and On? Go to step 5. Complete. 5 Are P/J42 and P/J422 connected correctly? Go to step 7. Reconnect the connector(s) P/ J42 and/or P/ J422 securely, then go to step 6. 6 Does the error still occur when the power is turned Off and On? Go to step 7. Complete. 7 Check the PHD XPRO Harness Assy for continuity. Disconnect P422 from the Imaging Unit. Disconnect J42 from the MCU Board. Is each cable of P422 <=> J42 continuous? Go to step 8. Replace the PHD XPRO Harness Assy. 8 Replace the Imaging Unit. Does the error still occur when the power is turned Off and On? Replace the MCU Board. Complete.